7
WARNING FOR INSTALLATION
LOCATIONS
•
Do not install the heater where
water, debris or flammable vapors
may get into the flue terminal . This
may cause damage to the heater
and void the warranty .
•
Do not have the vent terminal point-
ing toward any opening into a build-
ing . Do not locate your heater in a
pit or location where gas and water
can accumulate .
•
Do not install this water heater vent
terminator within 914 mm (3 ft .) of
any air intake or building opening .
(Refer to p .13 .)
•
Do not install next to a dryer or
any source of airborne debris that
can be trapped inside the combus-
tion chamber, unless the system is
direct-vented .
Clearances
Model
Top
Bottom Front
Back
Sides
T-KJr2-IN /
110
305mm
(12 in .)
305mm
(12 in .)
102mm*
(4 in .)
25mm
(1 in .)
76mm
(3 in .)
T-K4-IN /
310
305mm
(12 in .)
305mm
(12 in .)
102mm*
(4 in .)
25mm
(1 in .)
76mm
(3 in .)
T-D2-IN /
510
305mm
(12 in .)
305mm
(12 in .)
102mm*
(4 in .)
25mm
(1 in .)
76mm
(3 in .)
*610 mm (24 inches) recommended for maintenance .
Maintain all clearances around the water
heater .
The diagram of clearance
Included Accessories
Check that these items below are included with the water
heater .
Items
Installation Manual & Owner’s
Guide
Qty: 1
Communication Cable
(T-D2-IN / 510 models only)
Qty: 1
Temperature
remote
controller
T-KJr2-IN /110
&T-K4-IN /310
TK-RE02
Qty: 1
T-D2-IN /510
TM-RE30
Qty: 1
Optional Items
Model
T-KJr2-IN /
110
T-K4-IN /
310
T-D2-IN /
510
Universal
Appliance Adapter
(9008146005)
(2SVBFDPA04)
x
x
x
TK-TV10
x
x
x
TK-PC01
x
x
TK-PCJr2
x
Sidewall vent
terminator(Hood)
/ Termination Box
& Wall thimble
x
x
x
Direct-vent concentric
termination kit
(2SVSHTCKIT43S
or
2SVSHTCKIT43)
x
x
x
TK-IV01-AB
(Isolation valve kit)
x
x
x
914 mm
(3 ft.)
914 mm
(3 ft.)
914 mm
(3 ft.)
Vent
Terminal
V
WARNING
Prohibited
Top
Back
Side
Side
Front
Bottom