![Takagi GS-2000W-AU Installation Manual Download Page 17](http://html.mh-extra.com/html/takagi/gs-2000w-au/gs-2000w-au_installation-manual_814328017.webp)
17
FOR YOUR SAFETY, READ BEFORE OPERATING:
•
Check the GAS and WATER CONNECTIONS
for leaks before firing it for the first time.
• Open the main gas supply valve to the unit using only your hand to avoid any spark. Never use
tools. If the knob will not turn by hand, do not try to force it; call a qualified service technician.
Forced repair may result in a fire or explosion due to gas leaks.
• Be sure to check next to the bottom of the unit because some gases are heavier than air and
may settle towards the floor.
•
Check the GAS PRESSURE.
Refer to p. 11.
• Do not try to light the burner manually. It is equipped with an electronic ignition device which
automatically lights the burner.
•
Check for PROPER VENTING and COMBUSTIBLE AIR
to the heater.
•
Purge the GAS and WATER LINES
to remove any air pocket.
• Do not use this water heater if any part has been submersed under water. Immediately call a
qualified service technician to inspect the water heater and to replace any damaged parts.
CAUTION: IF YOU SMELL GAS:
• Do not try to start the water heater.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier,
call the fire department: “000”
INITIAL OPERATION
1
.
Once the above checks have
been completed, please clean filter
of any debris. Refer to p. 21 for
instructions.
2
.
Fully open the manual water
control valve on the water supply
line.
3
.
Open a hot water tap to verify
that water is flowing to that tap.
Then close the hot water tap.
4
.
Fully open the manual gas
control valve installed.
5
.
Turn on the 240 volt 50 Hz
power supply to the water heater.
6
.
Now you are ready to enjoy
hours of endless hot water.