Tuneup
General Information
14
August 2004© Tait Electronics Ltd
Table 1.4
CCTM commands in the transmitter category (part 1)
Command
Usage
Entry at keyboard
Response on screen
Transmitter category
33 – Transmit mode
Sets the radio in the transmit mode
33
None
47 – Temperature
Reads the temperature in the
vicinity of the PAs
47
x
y
where
x
is the ADC value of the
tem-perature (an integer from 0 to
1023) and
y
is the corresponding
voltage in millivolts (a value from 0
to 1200 mV)
114 – Transmitter power
Sets or reads the transmitter power
setting (compare command 326)
114
(to read value)
x
where
x
is the current power
setting (an integer from 0 to 1023)
114
x
(to set value)
where
x
is the required power
setting (an integer from 0 to 1023)
None
304 – Driver bias
Sets or reads the clamp current at
the gate of the PA driver
304
(to read value)
x
where
x
is the DAC value of the
clamp current (an integer from 0 to
255)
304
x
(to set value)
where
x
is the required DAC value
of the clamp current
(an integer from 0 to 255)
None
318 – Forward power
Reads the forward-power level
318
x
where
x
is the voltage in millivolts
corresponding to the power level
(a value from 0 to 1100 mV)
319 – Reverse power
Reads the reverse-power level
319
x
where
x
is the voltage in millivolts
corresponding to the power level
(a value from 0 to 1100 mV)
326 – Transmitter power
Sets the power level of the
transmitter
326
x
where
x
specifies the level
(0=off, 1=very low, 2=low,
3=medium, 4=high, 5=maximum)
None