TB9400 Specifications Manual
Module Specifications
43
© Tait Limited July 2017
2.3.2
Physical Details
2.3.3
Connections
Cooling
forced air over heatsink via front panel fan
Dimensions
Height
Width
Length
AC PMU
DC PMU
AC and DC PMU
143.5mm (5.6in)
121.4mm (4.8in)
324mm (12.8in)
337mm (13.3in)
337mm (13.3in)
Weight
AC PMU
DC PMU
AC and DC PMU
4.8kg (10.6lb)
5.1kg (11.2lb)
7.0kg (15.4lb)
The following specifications refer to the external wiring and connectors which are connected to the
PMU. They do not refer to the wiring and connectors built into the PMU itself.
AC input
Connector type
Current rating
IEC female
6A
DC input
a
Connector type
Recommended screw torque
Connector current rating
Flexible wire size
b
Flexible wire cross section
b
M6 screw into threaded fitting on bus bar
2–2.5N
·
m (18–20lbf
·
in)
a. Battery.
b. For a length of 1.5m to 2m (5ft to 6.5ft) (typical); the DC input leads should be of a suitable gauge to ensure no more
than 3% drop at maximum load over the required length of lead.
DC output - low current
(from auxiliary power supply)
Connector type
Flexible wire size
Phoenix MVSTBR2.5HC/2-ST/5.08 female
20AWG to 11AWG
12V
24V
48V
50A
2AWG
35mm
2
25A
5AWG
16mm
2
12A
8AWG
8mm
2