Reciter Fault Finding
77
© Tait Electronics Limited September 2006
Task 2 —
Check
Configuration and
Alarms
1.
Run the Service Kit and connect to the reciter. If the connection is
successful, check the state of the reciter. If it is in Run mode or
Standby mode, go to
. If it is in Download mode, go to
If the connection is unsuccessful, go to
2.
If the connection is unsuccessful, and the current measured in
is correct, proceed as follows:
■
Check that the communications port on the PC is configured
correctly.
■
Check that the connecting cables are fitted correctly, and the
Service Kit is set up correctly.
■
Check that the reciter is
not
in CCI mode. Try connecting to the
reciter at each of the different baud rates available in the Service
Kit. Start with the fastest speed, then try each slower speed in
turn. If the connection is successful, take the reciter out of CCI
mode and go to
. If it is not, continue with this Step.
■
Check that the 12.8MHz clock is present (go to
If the connection is now successful, check the state of the reciter. If
it is in Run mode or Standby mode, go to
. If it is in Download
mode, go to
. If the connection is still unsuccessful, return the
complete reciter to your nearest CSO for repair or replacement.
Note
If the Service Kit locks up during connection, use Windows Task
Manager to shut it down.
3.
Program the default profile into the reciter. Press Reset Base Station,
reset the power, and reconnect. If the connection is successful, go to
. If it is not, return the complete reciter to your nearest CSO
for repair or replacement.
4.
Once connected to the reciter, ensure it is in Standby Mode.
5.
Read the reciter and save the customer’s configuration file so that it
can be reloaded later if required. Record any feature sets that are
enabled so that they can be re-enabled before the reciter is returned
to the customer. Also check that there are no Task Manager
statements in the configuration which may affect the operation of the
reciter during testing.
6.
Select Monitor > Module Details > Reciter and check that the
module details are correct. If they are, go to
. If they are not,
return the complete reciter to your nearest CSO for repair or
replacement.
Summary of Contents for TB8100
Page 1: ...TB8100 base station Service Manual MBA 00016 02 Issue 2 September 2006...
Page 62: ...62 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Page 64: ...64 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Page 66: ...66 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Page 68: ...68 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Page 98: ...98 Reciter Fault Finding TB8100 Service Manual Tait Electronics Limited September 2006...
Page 108: ...108 Reciter Board Replacement TB8100 Service Manual Tait Electronics Limited September 2006...
Page 110: ...110 Reciter Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Page 112: ...112 Reciter Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Page 200: ...200 Power Amplifier Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Page 288: ...288 Subrack Servicing TB8100 Service Manual Tait Electronics Limited September 2006...
Page 294: ...294 Subrack Servicing TB8100 Service Manual Tait Electronics Limited September 2006...
Page 306: ...306 TB8100 Service Manual Tait Electronics Limited September 2006...