Tait TB7300 User Manual Download Page 15

Transportable Base Station/Repeater User’s Guide

Basic Operation

15

© Copyright Tait International Limited December 2020

External DC supply will not charge the internal battery.

Notice

When the transportable base station is not in use, always 

switch the battery select switch to External DC/Battery Isolate.

3.6

External AC Mains Connection

External AC mains must be connected to the unit using an AC power cable 
(see 

"Mains Socket Wiring"

) made up from the supplied Shurter AC plug 

with female socket (IEC320 10A IP67). AC mains can be used to charge 
the internal battery and to operate the unit.

3.7

LED Indication Details

3.7.1

Repeater

a. after the four power-up sequences

3.7.2

Status

This LED is lit when running on AC power, or switched to internal battery.

LED

Indication

Details

Repeater Power

green

repeater power is on

All LEDs/Alarm

flashing

power up sequence is in progress

Alarm

on

repeater is in offline mode

Alarm

flashing

a

an alarm condition needs to be cleared

Receive

orange

receiver is receiving

Transmit

orange

transmitter is keyed

LED

Indication

Details

Status

green

battery is fully charged or above 20% 
charged

Status

red, flashing

battery is low

Status

off

battery has been disconnected due to 
low voltage

Summary of Contents for TB7300

Page 1: ...TB7300 Transportable Base Station Repeater User s Guide MBD 00003 03 Issue 3 December 2020...

Page 2: ...y Rights This product may be protected by one or more patents or designs of Tait International Limited together with their international equivalents pending patent or design applications and registere...

Page 3: ...e to the PA 8 Environmental Conditions 8 Operating Temperature Range 8 Humidity 8 Dust and Dirt 8 Regulatory Information 9 Distress Frequencies 9 Compliance Standards 9 Unauthorized Modifications 9 He...

Page 4: ...tion as well as instruction in the proper use of the product This manual uses the following types of alert Warning This alert is used when there is a hazardous situation which if not avoided could res...

Page 5: ...io The same information is included in this user s guide MBD 00001 xx TB7300 Installation and Operation Manual MBD 00002 xx TB7300 Base Station Repeater Specifications Manual Publication Record Issue...

Page 6: ...ectrical blasting caps or in an explosive atmosphere Operating the equipment in these environments is a definite safety hazard 1 1 2 High Temperatures Take care when handling a repeater which has been...

Page 7: ...ure is calculated for a typical installation employing one 50W base station transmitter Other configurations including installations at multi transmitter sites must be installed so that they comply wi...

Page 8: ...ents switching or removing the load can damage the PA output stage See MBD 00001 xx TB7300 Installation and Operation Manual especially section 5 4 for recommendations 1 3 Environmental Conditions 1 3...

Page 9: ...e caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment 1 4 4 Health Safety and Electromagnetic Compatibility in Europe In...

Page 10: ...ectors can also provide a visual indication of unauthorized tampering Tait recommends that all network and audio connectors should be sealed with the stick on type of seal The seal should reveal if an...

Page 11: ...lies an external DC supply input Notice The Transportable Base Station Repeater was designed to be waterproof but should not be operated in the rain with the lid open An N type antenna connector on th...

Page 12: ...ning Risk of missing calls Switching between Internal Bat tery and EXTERNAL AC DC BATTERY ISOLATE will likely cause the transportable base station to restart When the switch is set to Internal Battery...

Page 13: ...operate to max 50 C ambient temperature 3 3 Battery Charging Warning Risk of fire The lid must be open when charging The VRLA battery may vent when charged at a current greater than 3A This does not o...

Page 14: ...the white protruding connector block 1 Carefully lift the new battery and place it in the battery slot Before tightening the captive panel screws ensure the battery connector is fully engaged To do th...

Page 15: ...67 AC mains can be used to charge the internal battery and to operate the unit 3 7 LED Indication Details 3 7 1 Repeater a after the four power up sequences 3 7 2 Status This LED is lit when running o...

Page 16: ...base station has an N type antenna connector Caution Risk of harm from RF radiation While the Repeater is oper ating transmitting you must ensure that there is always a distance of 0 9m between peopl...