M889-00
Fault Finding
5.9
Copyright TEL
02/10/95
5.5.3
Fan Control Circuitry
Key transmitter.
Does fan run at
room temperature?
Spray "freeze" on R116
or short R113.
Does the low temperature
inhibit circuit stop the fan?
Spray "freeze" on R116
OR short R113.
Check IC3 pin 14 >11V.
Check Q21 & Q20.
N
N
Y
Y
Check Q20 & Q21 collector
voltages. Check Q17 & Q18.
Check IC3 pin 14 <1V.
Check Q19.
Check Tx-key is low (at ground).
Do not key
transmitter.
Does high temperature control
circuit activate fan?
Heat R72 with tip
of soldering iron.
Check IC3 pin 8 >11V.
Check Q21 & Q20.
Fan control OK.
Heat R72 to >70°C with
tip of soldering iron.
N
Y
Summary of Contents for T889
Page 8: ...1 2 General Information M889 00 02 10 95 Copyright TEL ...
Page 14: ...2 2 Circuit Operation M889 00 02 10 95 Copyright TEL ...
Page 20: ...3 2 Introduction To Servicing M889 00 02 10 95 Copyright TEL ...
Page 30: ...4 2 Initial Tuning Adjustment M889 00 02 10 95 Copyright TEL ...
Page 34: ...5 2 Fault Finding M889 00 02 10 95 Copyright TEL ...
Page 42: ...5 10 Fault Finding M889 00 02 10 95 Copyright TEL ...
Page 43: ...M889 00 Fault Finding 5 5 Copyright TEL 02 10 95 ...
Page 46: ...6 2 Installation M889 00 02 10 95 Copyright TEL ...
Page 50: ...6 6 Installation M889 00 02 10 95 Copyright TEL ...
Page 52: ...7 1 2 PCB Information M889 00 02 10 95 Copyright TEL ...
Page 60: ...7 2 6 PCB Information M889 00 02 10 95 Copyright TEL ...
Page 63: ...M889 00 PCB Information 7 2 9 Copyright TEL 02 10 95 T889 PCB Layout Bottom Side 220 01326 01 ...
Page 65: ...M889 00 PCB Information 7 2 11 Copyright TEL 02 10 95 T889 RF Section 220 01326 01 ...
Page 66: ...7 2 12 PCB Information M889 00 02 10 95 Copyright TEL T889 Control Section 220 01326 01 ...