M2256-000-00-051
November 2001
CANCEL
(PC to A75)
The CANCEL command allows the PC to clear the currently received SDM data.
Example
An example of a ‘Cancel’ message is: c0110B
[IDENT]
c
[PARAMETERS]
[CANCEL_TYPE]
[PARAMETER]
Function
[CANCEL_TYPE]
A single ASCII hex character representing the cancelling type.
[CANCEL_TYPE] = 1
Delete SDM data
. This will delete last received SDM text data in the A75 EEPROM.
If there is no valid SDM data, it will do nothing.
Message Field
Parameter
Entered at
terminal
[IDENT]
CANCEL
c
[SIZE]
Size of parameter field
01
[PARAMETERS]
[CANCEL_TYPE] = 1 to delete SDM text
1
[CHECKSUM]
Refer to the
section
0B