6.9.2 Notes
Address (Hex)
Contents
Format Codename Access
Range & Unit
0064
0040H
0068
0044H
0067
0043H
0066
0042H
0065 0041H
0072
0048H
0071
0047H
0070
0046H
0069
0045H
RS
-
485 parity
RS
-
485 baud rate
RS
-
485 address
ADD
BRD
PAR
1~199
0~3
(Note 9)
0~6
(Note 10)
Integer
Integer
Integer
R/W
R/W
R/W
Note
Description
1
Integrated value byte order from high to low is
ntegrated value:
DCBA, if using tens digit calculation,
the i
D
*
2
^
48
+
C
*
2
^
32
+
B
*
2
^
16
+
A
5
4
3
2
10
9
8
7
6
Decimal position
:
0
:
No decimals
, 1
:
First decimal place, 2
:
Second decimal place
3
:
Third
4
:
Fourth decimal place
decimal places,
Flow units
:
0
:
ml, 1
:
L, 2
:
m³, 3
:
Gallon
4
:
in³, 5
:
、
6
:
7
:
8
:
kg, 9
:
lb, 10
:
ton
ml
m³,
in³
Time units
:
0
:
Sec., 1
:
Mins, 2
:
Hours, 3
:
Days
Relay1 status
:
0
:
Off, 1
:
Pulse
Relay2 status
:
0
:
Off, 1
:
Alarm set value, 2
:
Alarm error
Pulse units: 0
:
L, 1
:
m³
RS
-
485 Baud rate
:
0
:
2400
、
1
:
4800
、
2
:
9600
、
3
:
19200
RS
-
485
Parity
:
0
:
n.8.1, 1
:
n.8.2, 2
:
e.8.1, 3
:
o.8.1
Input square root
:
0
:
Off, 1
:
On
Zero resettable integrated energy
Zero resettable integrated flow
RST.E
RST.E
R/W
R/W
Integer
Integer
1: Reset