1.3 Setup and Operation
1.3.1 Menu setup
1.3.1.1 Menu setup
To explain menu setup of SDI series Matrix Switcher,
TMX-0808SDI serves as example.
TMX-0808SDI main interface:
Press “MENU” to enter main menu and press “
Õ
/
Ö
”
until “Setting” prompts; Press “MENU” again to enter
setup menu, including:
1. Ring
2. COM2 Baud rate
3. Demo Switch Delay
4. COM1 protocol
5. Sync Switch Delay
6. Test button
7. Video Track
8. Video Track Type
Press “EXIT” to exit menu.
Menu 1 to menu 8 are explained explicitly:
1. Ring
Buzzer ring on-off of this unit. If buzzer ring is setup
“on”, the buzzer will ring when front panel operation,
PC software executing switch and receiving command
from central control system. The buzzer ring can be
setup “off”.
ON: open ;
OFF: close.
2. COM2 Baud rate
SDI series Matrix Switcher has no COM2 port, so this
item can’t be adjustable.
1. Press “MENU” to enter setup menu and
press “
Õ
/
Ö
” until “Setting” prompts;
2. Press “MENU” and press “
Õ
/
Ö
” until “Ring”
prompts;
3. Press “MENU” to enter setup;
4. Press “
Õ
/
Ö
” to select parameter;
5. Press “MENU” to confirm.
Setting
Ring
OFF
Ring
▋
OFF
Ring
ON
Ring
▋
ON
Note:
)
When Video Tracking is off, RJ45 has
TCP/IP function.
)
When Video Tracking is on, RJ45 is
Invalidation; camera protocol can be
selected from Video Track Type menu;
RS422/RS485 can be connected to control
doom camera; TAINET can be connected to
congress main unit.
)
COM1 port can be connected to central
control system.
TMX-0808SDI
Version: 2.10
TMX-0808SDI
Version: 2.10
4