2.4 Connection
Typical system connection includes:
to another transmitter
to external audio sources
to emergency signal switch
to interpreter unit
to HCS-8300 Paperless Multi-media Congress
System
or
HCS-4100/50 Fully Digital
Congress System
2.4.1 To another transmitter
Bypass ( bypass) mode
The transmitter can be operated in bypass mode to
loop-through the IR radiator signals from another
transmitter. Multi room application can be achieved by
setting the transmitter in the center room to “Master”
mode and the transmitters in other rooms to “Bypass”
mode. One of the six radiator outputs of the master
transmitter is connected with an RG-59 cable to the
radiator signal loop-through input of the bypass
transmitter.
2 Transmitters should be set to “Master” and “Bypass”
separately (see section
Figure 2.4 Transmitter connected to another transmitter
in bypass mode
2.4.2 To external audio sources
HCS-5100M/F transmitter has up to 40 audio inputs
(depends on transmitter type) for connecting to
external unbalanced audio sources (such as other
brand conference systems) or for music distribution.
Figure 2.5 Transmitter connected to external audio
sources
2.4.3 To emergency signal switch
To use emergency function, fire alarm linked trigger
interface (normally open) must be connected to the
emergency switch connector. When the switch is
closed, the audio signal on the Aux-Right input is
distributed to all output channels and overriding all
other audio inputs.
“ALARM” will be displayed on the LCD at this moment.
Figure 2.6 Transmitter connected to emergency signal
switch