16
Now the REC indicator light on the front panel of CMU will
turn on or flash and it will turn off when the storage
capacity is less than 10 M (stop recording).
3).
Press the “MENU” button to stop and save the record.
UUU
b). Playback
1).
After enter the playback interface, press the “
×
/
Ø
”
button to select a recorder media;
2).
Press the “
×
/
Ø
” button to select a record and press
the “MENU” button to entre;
The record is named according to the recording time, for
example, a file by the name of “140611 095110” means it
is recorded at 09:51:10 on 2014-06-11.
3).
Press the “MENU” button to playback;
4).
Press the “MENU” button to stop or continue playing;
5).
Press the “
×
/
Ø
” button to select
and press the
“MENU” button to turn off, and then press the “EXIT”
button to exit.
2.1.3.3
Network Setting
“Network Setting” includes three submenus:
Æ
“IP address”
Æ
“Subnet Mask”
Æ
“Gateway”
UUU
a) Setting up unique “IP Address” for the main unit:
1).
Select “IP address” and press the “Menu” button to go
to setup IP address interface:
2).
Use “
×
/
Ø
” to switch between the four numbers;
3).
Use the “MENU” button to edit selected number;
4).
Use “
×
/
Ø
” to increase/decrease the number;
5).
Press “EXIT” to save and return to the upper level
menu.
UUU
b) Setup “Subnet Mask” and “Gateway”
Same chronological order as for “IP address” set up.
2.1.3.4
Test
Test the LEDs of the conference units.
The LEDs on all connected contribution units will blink
immediately. Press the “EXIT” button to exit the LED test
interface.
2.1.3.5
Active Mic(s) Status
Display the current status of active microphones; include
the ID number, gain and lowcut.
Note:
)
Because playback will use an audio channel, at
most 5 microphones can be active when playback.