background image

11 

 

Once the salt remaining has gone below the set point, the display will automatically shows “SALT LEVEL IS 

LOW” on the screen and a word “ALERT” flashes. 

 

RESETTING THE SALT AMOUNT AFTER ADDING 

Step 1 – Press the NEXT button until SALT LEVEL appears in the display. 

Step 2 – Press CLOCK. 

Step 3 – Use UP or DOWN to adjust the pounds remaining in the brine tank. Estimate the pounds of salt in 

the brine tank and add it to the amount of salt added to the brine tank. 

Example: 200 lbs. of salt being added to a brine tank that has 40 lbs before adding, the number of 

SALT LEVEL should adjust to 240. 

Step 4 – Press CLOCK to exit Salt Level Set. 

Step 5 – Press NEXT to return to TIME OF DAY. 

 

START UP INSTRUCTIONS 

  After installation is completed rotate the bypass handles to the bypass position (see bypass valve diagram 

page ). 

  Turn on water and check for leaks. 

  Fully open a cold water faucet. 

  Allow water to run until clear to rid pipes of debris which may have occurred during installation. 

  The system is now ready for filling with water and for testing. 

 

1.  With the bypass valve in the bypass position, manually pour enough water into the brine tank to reach 

the top of the air check valve. 

 

2.  Press and hold the REGEN button until the motor starts. Release button. Wait until the display reads 

“BACKWASH”  and  the  remaining  time  is  counting  down.  Unplug  transformer  to  prevent  valve  from 

moving to the next cycle. 

 

3.  Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to 

expel air. 

CAUTION: If water flows too rapidly there will be a loss of media. 

 

4.  When the water is flowing steadily to the drain without the presence of air, restore power and momentarily 

press the REGEN button to advance the control to the “BRINE” position. 

 

5.  Fully open the inlet bypass valve handle (bypass is now in the diagnostic position). 

Check to verify that water is being drawn from brine tank.  There 

should be a slow flow to the drain. 

Allow two minutes for the media bed to settle. 

 

6.  Momentarily  press REGEN  again  until  the  display  reads “2  BACKWASH”  and  the  “time  remaining” 

numbers are counting down. The “2” flashes. 

 

7.  Momentarily press REGEN again until the display reads “RINSE”. Unplug transformer. There should be a 

rapid flow to the drain. Allow to run until steady, clear, and without air. 

Restore power. 

 

8.  Set bypass valve handles to the normal operating position 

 

9.  Momentarily press REGEN again until the display reads “FILL”. 

Allow the brine tank to fill automatically. 

It will fill with the proper volume of water for the first regeneration after the unit will automatically return 

to the service position. If not filling automatically, press REGEN to advance the valve to service. 

 

10.  While the brine tank is filling, load it with water softener salt. 

 

 

 

 

 

 

 

 

Summary of Contents for T../MA-BTB series

Page 1: ...E PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN...

Page 2: ...which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times salt dose exchange capacity and gallon capacity regeneration time...

Page 3: ...gh them When moving through any displays or programmings if no buttons are pressed within five minutes the display returns to normal operating displays Any changes made prior to the five minute time o...

Page 4: ...5CS Press UP or DOWN until FILL appears Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Press UP or DOWN until END appears Press NEXT to exit Cycle Sequence Press REGEN t...

Page 5: ...ss as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time T...

Page 6: ...f no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Press NEXT until SALT LE...

Page 7: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Page 8: ...sure relief valve Also be certain that local codes are not violated 4 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to room temperatures...

Page 9: ...allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into the conditioner INSTALLER SETTINGS Step 1I Press NEXT and UP simultaneously fo...

Page 10: ...l the error or alert is reset by the user Press NEXT to exit Installer Display Setting Press REGEN to return to the previous step SET TIME OF DAY Time of day should only need to be set if the battery...

Page 11: ...maining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Someti...

Page 12: ...ACKWASH and the remaining time is counting down Unplug transformer to prevent valve from moving to the next cycle 3 Open the inlet handle of the bypass valve very slightly allowing water to fill the t...

Page 13: ...12 REPLACEMENT PARTS...

Page 14: ...13 REPLACEMENT PARTS...

Page 15: ...14 REPLACEMENT PARTS...

Page 16: ...15 REPLACEMENT PARTS...

Page 17: ...16 REPLACEMENT PARTS...

Page 18: ...17 INSTALLATION FITTING ASSEMBLIES...

Page 19: ...orce on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner Pressing to the left helps the drive gears mesh with the drive cap...

Page 20: ...t may be used on black o rings but is not necessary Avoid any type of lubricants including silicone on red or clear lip seals Reinsert the drive cap assembly and piston into the spacer stack assembly...

Page 21: ...ing dilute sodium bisulfite or vinegar Do not use a wire brush If necessary replace the flow control flow control retainer o ring or the elbow o ring Reseat the flow control so the rounded end with le...

Page 22: ...tating the assembly as you pull it out will enable it to be removed more easily There are three o rings one under the rotor cap one on the rotor stem and one on the rotor seal Replace worn o rings Cle...

Page 23: ...assy d Piston not in home position d Press NEXT and REGEN or momentarily unplug PC board power e Motor gears not fully engaged Motor wires broken Failed motor e Check motor and wiring f Center drive g...

Page 24: ...23 Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204 783 1599 fax www waterite com...