XT-1/XT Mini Manual
13-111 05, 2015-08-14
Page 14 of 32
t
SU
t
PI
t
PW
t
H
t
R
t
F
CL
D0
D1
≈
≈
≈
Figure 12 Wiegand timing diagram
3.3.2 Magstripe Timing
The following values apply when all outputs are pulled up to 5 V with 1 k
Ω
resistors.
Symbol
Parameter
Min
Typ
Max
Unit
t
SU
LOAD to CLK setup time
1520
µ
s
t
F
Fall time (all signals)
125
ns
t
R
Rise time (all signals)
5
µ
s
t
CL
Clock low
480
µ
s
t
CH
Clock high
960
µ
s
t
H
LOAD hold time after last CLK change
1520
µ
s
t
DH
Data hold time
880
µ
s
Table 7 Magstripe interface timing
≈
≈
t
SU
LOAD
CLK
DATA
≈
t
CL
t
CH
t
DH
t
H
t
R
t
F
Figure 13 Magstripe timing diagram (note: data low = logic one)
Ethernet
The reader has a 10 Mbps/100 Mbps Ethernet interface with one (XT Mini) or two (XT-1) ports. The interface
supports auto crossover (Auto-MDIX) so that installation can be done using either patch cables or crossover
cables. Each port has two LED indicators for Link/Activity (Yellow/Flashing Yellow) and 10 Mbps/100 Mbps
speed (Off/Green).
Connections
ETHERNET:A
Ethernet port
ETHERNET:B (XT -1 only)
Ethernet port
Max cable length
100 m
Wire size
CAT5e cable or better is required for the Ethernet connection
Table 8 Ethernet connection overview
The reader's default IP address and subnet mask can be found on a label on the backside of the reader.
The default address is on the format 10.x.x.x and the subnet mask is 255.0.0.0. All IP settings can be
Summary of Contents for XT-1