7
Operation
Note!
This unit requires a single-phase 3-conductor electrical outlet.
1. Plug the Power Cable to the filter and into the electrical outlet.
2. Turn on the filter (the Power Switch should be in the upper ON position).
The Power Indicator should light up – if not then check the connection
to the electrical outlet and whether it is powered.
3. Phase Indicator
- the indicator will illuminate when the phase is incorrect.
If the Phase is incorrect perform the following steps:
a)
Schuko type electrical outlet. Make sure the filter is turned off (the Power Switch is in
the down OFF position and the Power Cable is removed).
Remove the power plug from the outlet, reverse the plug by 180 degrees and put it into
the outlet.
Turn on the filter – the Phase Indicator should switch off – the Phase is correct.
b)
Electrical outlet with a ground pin. Make sure the filter is turned off (the Power
Switch is in the down OFF position and the Power Cable is removed).
Contact a qualified electrician to reverse wiring connection in your electrical outlet.
Turn on the filter – the Phase Indicator should switch off – the Phase is correct.
Note!
Due to risk of electric shock refer any changes related to electrical equipment to
qualified personnel.
4. The Power Sockets in your filter may have additional marking related to the female
contacts: L – LIVE | N – NEUTRAL.
If not then check the below figure showing the Power Sockets wiring (for the
correct Phase).