background image

2

Introduction

Thank you for purchasing this TAGA Harmony power line conditioner. 

 

The electricity network in our homes or workplaces is exposed to different interferences 

for instance electromagnetic interference (EMI) generated by appliances connected to 

the same network (refrigerators, air conditioners, computers etc.). These interferences 

are not only produced inside your house or office but by all appliances in your building 

or even outside it and can differ on the time of day or week when the traffic on the

 

electrical network changes. 

All these interferences which we call noises can get into your AC power and interfere 

with your system. 

This “dirty” electricity can have a negative effect on performance of your audio-video 

system. 

 

TAGA Harmony power line conditioner is a next level, effective and reliable protection 

against voltage fluctuations and line disturbances (noises) which can negatively impact 

your audio-video system. 

 

Thanks to our PC power line conditioners you will be able to enjoy a better quality of 

your audio and video equipment.

The contaminated electricity has also a negative impact on internal circuits and power 

supplies of your equipment and because the PC conditioner works as a buffer between 

the wall socket and your gear it will help to increase the longevity of the connected 

components.

Features:

•  Independent groups of switched and unswitched power sockets

 (Schuko type) 

specifically designed for use with different audio and video equipment.

•  Voltage meter

 (selected models) to control stability of the power voltage in the wall 

outlet.

•  Phase detection

 indicates the incorrect power phase and the Polarity Switch allows 

to easily correct it.

• 

Diversified duplex filtering

 based on a high-quality Class-X capacitors and 

inductors.

•  High power toroidal transformer

 to isolate equipment from the line noise.

•  Spike and surge protection

 to protect against everyday high energy spikes 

and transient voltages.

•  Primary lightning surge protection

 to protect of the load equipment from effects of 

high transient over-voltages following a lightning strike (introduced indirectly into the 

utility mains).

•  Removable IEC type power cord 

gives an option to upgrade your system with a 

premium audiophile power cable in any time.

Cleaning

Do not use strong or abrasive cleaners. Use a dry, soft cloth for cleaning.

Specifications

Full technical specifications are available on the 

www.TagaHarmony.com

 website.

Summary of Contents for PC Series

Page 1: ...PC Series 230V POWER LINE CONDITIONER FOR USE WITH AUDIO VIDEO EQUIPMENT Instruction Manual Edition 03 2020 ...

Page 2: ...ct on internal circuits and power supplies of your equipment and because the PC conditioner works as a buffer between the wall socket and your gear it will help to increase the longevity of the connected components Features Independent groups of switched and unswitched power sockets Schuko type specifically designed for use with different audio and video equipment Voltage meter selected models to ...

Page 3: ...3 Contents Safety Instructions 4 Controls and display 6 Hooking Up the Conditioner and Operation 7 Kit Content 11 ...

Page 4: ...ON FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE THE FUSE IF THE UNIT IS EQUIPPED WITH A USER REPLACEABLE FUSE ONLY WITH THE SAME AMPERAGE AND VOLTAGE TYPE IN CASE WHEN THE UNIT IS NOT EQUIPPED WITH A USER REPLACEABLE FUSE REFER REPLACEMENT TO QUALIFIED SERVICE PERSONNEL WARNING THE UNIT MAY BECOME HOT ALWAYS PROVIDE ADEQUATE VENTILATION TO ALLOW FOR COOLING DO NOT PLACE THE UNIT NEAR A HE...

Page 5: ...ed on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the product 12 Lighting For added protection for this product during a lighting storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or system cables This will prev...

Page 6: ...rate this switch when the conditioner is connected to the electrical outlet this may damage the conditioner and or connected devices this may void your warranty Make sure to disconnect the Power Cable before operating the Polarity Switch A blown fuse should be only exchanged for exactly the same type as indicated on the rear conditioner panel above the Fuse Box The Power Cable should be disconnect...

Page 7: ...correctly the equipment power cable plug to the power line conditioner according to the polarity marking Hooking Up the Conditioner and Operation The Phase Detection is not related to the Power Switch and is always active when the conditioner is connected to the electrical outlet TOP 9 Switched Power Sockets Group I recommended for digital equipment Group II recommended for sound sources 10 Unswit...

Page 8: ...L N L N L N L N N L N L Group I 3A max Group IV 5A max N L N L Group III 5A max Group III Preamplifiers Accessories Preamplifier Phono Stage Headphone Amplifier PC 5000 SWITCHED Group II 1A max UNSWITCHED L N L N L N L N N L N L Group I 3A max Group IV 5A max N L N L Group III 5A max Group IV Amplifiers Power Amplifier Solid State Hybrid Tube Integrated Amplifiers AV Receiver PC 5000 SWITCHED Grou...

Page 9: ...r digital equipment DAC Music Streamer Media Player BT receiver Group II low power inductance filtering isolated by the power transformer of Power Sockets is recommended for sound sources CD DVD Blu ray Player Turntable Radio Tuner Note Group II is specially designed for sound sources Do not connect other equipment to the Power Sockets in this group UNSWITCHED POWER SOCKETS These sockets are not c...

Page 10: ...ase 3 conductor electrical outlet We recommend to use Schuko plugs in all power cables Make sure not to overload the power line conditioner and individual groups of Power Sockets Power load for each group of Power Sockets the total maximum power consumption for all connected devices to a given group should not exceed the maximum power load for this group The maximum load for each group is given in...

Page 11: ...t Directive do not dispose of this product as household waste or commercial waste Waste electrical and electronic equipement should be appropriately collected and recycled as required by practices established for your country For information on recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product Your prod...

Page 12: ...12 Note ...

Reviews: