9
Phase Detection
A. Make sure that the Polarity Switch is set on 1 (default).
It determines the polarity in the female contacts in the Power Sockets:
• floor-standing models - according to the L and N marking on the top panel.
• shelf models - if the L and N marking is not provided, as shown in the figure below
(view on the rear panel from the back).
B. Without connecting any external equipment plug the Power Cable to the
conditioner and into the electrical outlet.
C. The
Phase LED Indicator
WILL ILLUMINATE when the phase is INCORRECT.
If the phase is incorrect then:
d1- Remove the Power Cable from the electrical outlet;
d2- Set the Polarity Switch to 2;
Setting the Polarity Switch to 2 will exchange the polarity in the Power Sockets of
the conditioner (L → N and N → L).
Make sure to consider this when connecting the external equipment.
d3- Connect the Power Cable to the electrical outlet;
d4- The Phase Indicator should not be illuminated - the phase is correct.
D. If your audio-video equipment has the polarity marking (L/N) make sure to connect
correctly the equipment power cable plug to the power line conditioner according
to the polarity marking.
Hooking Up the Conditioner and Operation
The
Phase Detection
is not related to the Power Switch and is always
active when the conditioner is connected to the electrical outlet.
Never operate this switch when the conditioner is connected to the
electrical outlet – this may damage the conditioner and/or connected
devices – this may void your warranty.
Make sure to disconnect the Power Cable before operating the Polarity
Switch!
Connecting audio-video equipment
2. Make sure the conditioner is turned off (the Power Switch is in the down OFF
position and the Power Cable is removed).
3. Using power cables (only a power cable for the conditioner is supplied with this
product) connect your audio-video equipment to the Power Sockets following the
Phase Detection recommendations.
Follow the below recommendations for connections: