2.  General use 

 
To preserve power, turn OFF the device when not in use. 
 
Once the detector is correctly positioned on its holder, (the fixing system is a ¼ inch screw-
thread - traditional camera tripods or our TAG Heuer HL5), turn the switch clockwise in 
order to turn the device ON.  
 
Check that it receives the desired sound signal (like a start pistol or a clap). Adjust the 
sensitivity so that the device is not activated by other undesired sounds.  
 
 
 
 

3.  Power supply and Battery replacement 

 

You will find the Battery inside the rear removable cover. The Battery type is a 9V 6LR61.  
 

 

 
 
 

4.  Technical specifications. 

 

Sound detector with dynamic  microphone. 
Adjustable detection threshold 
Power supply: 9V type 6LR61  
PVC casing IP54 with Screw-thread fixation: ¼ inch (fits on our HL5 and HL4 series) 
Bandwidth: 100 to 10000 Hz 
Max sensitivity at 1metre (3.3 feet) 55 dB 
Min sensibility at 1metre (3.3 feet) 105 dB 
 
 
 
 
 