tae TA-05KB-SMD Instructions & Operating Manual Download Page 3

TA-05KB-SMD & TA-1K-SMD

Instruction and Operating Manual

We reserve the right to correct technical and printing errors

3

Connection of the drive control  (refer to connectiondiagramm)

Ensure that your a.c. line voltage corresponds to the voltage shown on the type marking of the unit. 

Terminal strip

1 – 2 

AC input, voltage according to type marking on unit, frequency 50 or 60 Hz, terminal 1 

-phase, terminal 2 -neutral.

3 – 4 

Armature, terminal 3 + (positive), terminal 4 -(negative). 

5 - 6 

Field, terminal 5 + (positive), terminal 6 -(negative). 

7 – 8 

Drive control release, contact closed = released (run). 

12 

Reference input (positive) without acceleration. Input voltage depends on rating of re-

sistor R1, however max. voltage 150VDC Input current approx. 0,32mA at max. speed.

 

Calculation of R1 as follows:

 

R1 (kOhm) = 3 x U

E

(V) - 30 

 

If terminal 12 is used, speed potentiometer must be disconnected. 

 

Terminals 10 and 11 must be interconnected, min. speed potentiometer P1 must be 

set fully counter clockwise. 

13 - 14 

DC tachometer, terminal 13 + (positive)(electronic ground), terminal 14 -(negative) 

(approx. 150 V at rated motor speed). Matching of tachometer with R36. 

9 - 10 - 11 

Speed potentiometer, connect center to terminal 10, start to terminal 11 and end to ter-

minal 9. This potentiometer enables an infinite variable adjustment of the motor from 
min. to max speed. 

Drive control adjustment 

Min. RPM 

P1  Adjustment of minimum speed during operation.

Acceleration rate 

P2  Adjustment of the acceleration time of the motor from min. to max. speed.

 

The acceleration time can be adjusted from 2 to 10 sec. 

Max. RPM 

P3  Adjustment for maximum speed during operation.

I x R compensation  P4  This control permits to compensate for the voltage drop in the armature and in 

the supply line when armature feedback control is utilized. When tachometer 
feedback is used, set this potentiometer fully counter clockwise .

Current limit 

P5  Adjustment of the requested armature current. Max. permissible armature cur-

rent 7A DC at TA-05KB and 10A DC at TA-1K.

Stability 

P6  With this potentiometer the drive is dynamically adapted to the load.

Indicator lamps

The following functions are indicated by light emitting diodes (LED‘S):
a)  Control release 

yellow  LED 1

b)  Line 

green 

LED 2

c)  Current limit/over speed  

red 

LED 3

Summary of Contents for TA-05KB-SMD

Page 1: ...ikatron GmbH division TAE Antriebstechnik Raiffeisenstrasse 10 D 61250 Usingen Warnung As with any form of electrical equipment there is always a risk involved in the handling of electrical machinery The greatest care must always be exercised during installation and maintenance and it is recommended this be carried out by authorized personnel ...

Page 2: ...max 10A Field voltage 210V Field current max 0 5 Ampere max 0 6 Ampere Ambient temperature 0 40 C Speed accuracy 3 with armature feedback 1 with tachometer feedback Semi controlled single phase bridge inner loop current regulator acceleration integrator Table of content 1 Technical data 2 2 Connection of the drive control refer to connectiondiagramm 3 3 Drive control adjustment 3 4 Indicator lamps...

Page 3: ...round terminal 14 negative approx 150 V at rated motor speed Matching of tachometer with R36 9 10 11 Speed potentiometer connect center to terminal 10 start to terminal 11 and end to ter minal 9 This potentiometer enables an infinite variable adjustment of the motor from min to max speed 3 Drive control adjustment Min RPM P1 Adjustment of minimum speed during operation Acceleration rate P2 Adjustm...

Page 4: ...r speed with P3 max speed for the requested maximum value Now turn the speed potentiometer fully counter clockwise the output voltage must drop back to 0 V and the potentiometer P1 min speed can now be adjusted for the requested minimum speed 9 Adjust the I x R compensation with potentiometer P4 Check for approximate equal speed with and without motor load in the lower speed range When the potenti...

Page 5: ...ED 2 line does not light up c defective fuse Si 10A FF TA 1K 16A FF TA 1K d relay K1 is defective a motor load is to high b defective speed potentiometer c current limit is set to low Relay K1 is not energized when drive is re leased yellow diode LED 1 does not light up Drive runs unstable a I x R compensation is set to high when armatu re feedback controlled b defective tachometer or tachometer l...

Page 6: ...r defective tachometer b check armature feedback c potentiometer P3 max speed is defective Drive runs after release at maximum speed wit hout keeping reference value preset speed a intermittent potentiometer P1 min speed b intermittent speed potentiometer or intermittent wiring from terminal 11 to potentiometer Motor starts immediately when connected to AC line without drive being released a groun...

Page 7: ...ng Manual We reserve the right to correct technical and printing errors 7 7 Connectiondiagramm 1 2 3 4 5 7 8 9 10 11 12 13 14 6 M T V A ND GD Ph MP Line Armature Field Run Speedpotentiometer Signal input DC Tachometer A E S TE TA 05KB TA 1K Ground ...

Page 8: ...Operating Manual TA 05KB SMD TA 1K SMD We reserve the right to correct technical and printing errors 8 8 Dimensions 8 1 TA 05KB with mounting plate 8 2 TA 05KB 112 5 125 185 170 53 8 ø8 ø4 90 100 160 150 43 10 ø6 ø3 2 ...

Page 9: ... SMD TA 1K SMD Instruction and Operating Manual We reserve the right to correct technical and printing errors 9 8 3 TA 1K with mounting plate 8 4 TA 1K 112 5 125 185 170 53 8 ø8 ø4 90 100 160 150 43 10 ø6 ø3 2 ...

Reviews: