Misprints as well as technical changes reserved
EFM2000.DOC HS 03/98 V3.260298.GB.002
7
In order to change the indicated parameter the decimal point must be moved to the
individual display unit by pressing key
T1
. The indicated number of this display can now be
altered by pressing key
T2
.
If key
T1
is pressed again the system returns to the parameter counter
P
.
Pressing now key
T2
again will increase the parameter counter to the next parameter. At
the end of the algorithmical adjustment the parameter counter will return to the opterating
mode and the new values of the parameters are stored. The FM 2000 will now operate with
the set new parameters.
NOTE: This newly set parameter cannot be cancelled if the line voltage is interrupted!
All parameters can be changed as often as requested and any parameter which is not to
be changed can be scipped with the parameter counter by selecting the next parameter.
5.0 Multiplier Adjustment
When the parameter counter
P
shows the number 1 it is possible to set a multiplier for the
actual measuring value. The standard value is 01000.
This standard value corresponds to the multiplier 1.0. If for instance the factor 0.5 is
requested the parameter must then be adjusted to 00500.
P
T1
lights up
T2
Figure 3:
Display of the FM 2000 for multiplier adjustment
The requested segments (1 to 5) can be activated with key
T1
. The decimal point of the
activated segment lights up. The figures can now be selected with key
T2
. Activating key
T1
will return the system to the parameter counter
P
after the parameter 1 has been
completely adjusted.