FAQ: 

 

1. Is it possible to connect system to large distance 400 ft? 

 
Possible, but need to make sure below details during installation: 
1. Good cable preferred twisted cable 2 x 1 mm 
2. PC6A should be nearest as possible to the monitor inside the house. 
3. Just to make sure, monitor need to get 24V, so if you can connected and check the power that arrives to the 
monitor is 24V it should be working 
this is why good cable is very important. 
 

1.

 

Bus from Monitor goes to PC6A 

2.

 

Bus from PC6A goes to the panel Bus 

3.

 

Relay  : connects to electric lock in your situation you can connect it directly to gate command to open 
the gate  

4.

 

Rex : if want to install bypass button to open the door by pressing a button  

 
2. Unit doesn’t show Picture / Audio? 

It may be a problem with infrastructure check below: 
Disconnect the unit and connect again in a short distance between the monitor, panel and PC6A 
if unit show picture, there might be a problem with wires quality or distance. 
+ Try to improve the cable quality 
+ Try Reduce distance between PC6A and Monitor.

 

  

Summary of Contents for TOPAZ

Page 1: ...1 English TOPAZ User Guide TOPAZ ...

Page 2: ... to work under hard weather conditions Allow to see the visitor and open the from the monitor by single click 2 Specifications Can work with telephone calling with additional Tele adapter Require 2 wires only Can work with mobile calling with additional GSM adapter Possible to connect 32 monitor for system 102 wide degree angle Possible to connect 4 Panels for system Panel with 1 2 4 calling butto...

Page 3: ...ount of monitors Description Transformer type 1 Up to 3 24V 4 5A Ns 100 2 Up to 7 24V 6 5A Ns 150 3 Up to 32 24V 14 6A Ns 350 Lock Type Electric or magnetic Normally open או Normally close Sizes Flush Mount 28 90 170 Surface 36 116 213 4 Cable Distance Information ...

Page 4: ...4 5 Installation diagram A Topaz Panel 1 Monitor B Topaz panel more than one monitor ...

Page 5: ...5 250mA we advise to use external power supply for maximum results as 250mA is lock that made for small voltage and might be to weak for the system ...

Page 6: ...6 ...

Page 7: ...7 The door station is also compatible with other monitors which our provided by Tador It can be extended 3 slave monitors for each monitor Better use with extra distributer for extension ...

Page 8: ...e is very important 1 Bus from Monitor goes to PC6A 2 Bus from PC6A goes to the panel Bus 3 Relay connects to electric lock in your situation you can connect it directly to gate command to open the gate 4 Rex if want to install bypass button to open the door by pressing a button 2 Unit doesn t show Picture Audio It may be a problem with infrastructure check below Disconnect the unit and connect ag...

Page 9: ...r buying one of our products All rights reserved Tador Technologies LTD 9 Thank you for buying one of our products www Tador com All rights reserved Tador Technologies LTD All rights reserved Tador Technologies LTD ...

Reviews: