FAQ:
1. Is it possible to connect system to large distance 400 ft?
Possible, but need to make sure below details during installation:
1. Good cable preferred twisted cable 2 x 1 mm
2. PC6A should be nearest as possible to the monitor inside the house.
3. Just to make sure, monitor need to get 24V, so if you can connected and check the power that arrives to the
monitor is 24V it should be working
this is why good cable is very important.
1.
Bus from Monitor goes to PC6A
2.
Bus from PC6A goes to the panel Bus
3.
Relay : connects to electric lock in your situation you can connect it directly to gate command to open
the gate
4.
Rex : if want to install bypass button to open the door by pressing a button
2. Unit doesn’t show Picture / Audio?
It may be a problem with infrastructure check below:
Disconnect the unit and connect again in a short distance between the monitor, panel and PC6A
if unit show picture, there might be a problem with wires quality or distance.
+ Try to improve the cable quality
+ Try Reduce distance between PC6A and Monitor.