Coral IPx Office Installation Manual
Peripheral Cards
10-3
Peripheral Car
d Installati
on
10
0
Each plug-in Office service and peripheral card is equipped with one or two red
diagnostic indication LEDs on the front side, near the right side of the card
1
. These
LEDs can assume one of three states of illumination: OFF, ON, or FLASHING. The
illumination state of the LED indicates the card's operating condition.
the indication provided by each of the three LED states.
During normal operation, the card diagnostic LED should be extinguished. However,
the LED routinely illuminates steadily whenever power is first applied to the system,
the entire system is initializing, or the card is first inserted into a card slot. The LED
remains illuminated steadily until the card receives a card database from the system.
LED Constantly Lit
If the LED stays lit for more than two or three minutes, a problem may exist within the
card. The most likely problem is a conflict with the system database, although it also
may be an actual malfunction of the card circuitry.
Table 10-1 Card
Diagnostic LED Indications
The system database will prevent a card from initializing:
When the card is inserted into a card slot that has been initialized with
another card type.
Check the Card List branch (Route: CLIS) in the database, to determine
whether the card slot has been previously initialized with a different card
type. If the STATUS field shows CARD REPLACED, and the I_TYPE for
the card slot shows a different card type, enter NO_CARD to clear the slot.
There are insufficient system resources allocated in the System Sizes
Definition to support the new card. The STATUS field in the Card List
branch (Route: CLIS) shows NO RESOURCES. Check the Sizes branch
(Route: SIZ) in the database to determine the maximum number of ports of
the type provided by the problematic card, and then determine how many
of these ports are already installed. If the additional ports provided by the
...................................................................................................
4
Diagnostic LED Indication
1. In the U-RMI Office and U-MR Office card a second LED is located in the middle of the
card.
In the 4S+8/16Fx Office, 4SA+/816Fx Office, 8S+8/16Fx Office and 8SA+8/16Fx Office
cards a second LED is located in the right side of the card.
LED State
Indication
Extinguished OFF
No problem with the card, it is functional.
Steadily lit - ON
Card has not received a card database from system.
Flashing
Diagnostic test failed by circuitry on card.
Summary of Contents for Coral IPx Office
Page 2: ......
Page 4: ......
Page 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Page 26: ......
Page 28: ......
Page 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Page 44: ......
Page 96: ......
Page 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Page 122: ......
Page 138: ......
Page 182: ......
Page 234: ......
Page 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Page 260: ......
Page 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Page 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Page 312: ......
Page 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Page 420: ......
Page 488: ......
Page 509: ......