  Mis-operation occur during unit working: 

  In case mis-operation caused by lighting or vehicle radio, cut off the manual 

power switch, and turn it on again, afterword press RUN/STOP key.   

  It is  forbidden  to  switch  the  power off if  ambient  temperature  below -7

.  In 

case of power failure or power need to be cut because of maintenance, please 

open the drainage valves at the joints of water inlet and outlet pipes as soon 

as possible to draining out all water. Otherwise, components inside of the units 

may  be  damaged  by  freeze.  Upon  draining  water,  please  close  the  water 

drainage valves. 

 

Shut-off memory   

Every  time  when  power  is  shut  off,  the  controller  will  save  the  current  operate  status 

automatically, when power come on the next time, controller will send the ON/OFF signal to 

the water heater according to the memory before power shut off. The function keeps unit 

always working on the mode which was set in the last time before power failure. 

 

About RCCB 

  Outdoor  unit  must  use  RCCB,  be  install  a  RCCB  between  in  user  power  supply  and  the 

outdoor unit. In case the unit cannot act but not attribute to power failure, please check these 

RCCB switches at first. Before operate the RCCB, be ensure that the user installing switch 

is break off. 

  After the RCCB has serviced for a period of time, it is necessary to press the test button at 

close circuit to check whether the performance of RCCB is work normally (Every time you 

press this button, RCCB break up once). In case malfunction occurs, but no cause was found, 

it is permit to delivering power to detect failure. If RCCB doesn’t work when being powered, 

check out the cause by feature if necessary. If which is detected and confirmed as its self-

malfunction, consign a professional person repair it or replace it for a new one. 

 

2.12 Wire controller 

Wire controller KJRH-90B/E is used to accept the user’s order and to send it to main control board, 

meanwhile receives operating states and display specifications.   

  The wire length of the wire controller is 1m. 

  After  finish  operating  the  wire-controller,  the  wire-controller’s  waterproof  box  must  be 

covered to prevent rain damage. 

 

 

The appearance of controller 

Summary of Contents for Ansal LRSJ-80/NYN1

Page 1: ...n Domestic Pool Type Heat Pump Water Heater Technical Manual Applicable Model LRSJ 60 NYN1 LRSJ 80 NYN1 LRSJ 120 NYN1 LRSJ 140 NYN1 Tadiran reserves the right to discontinue or change specification or...

Page 2: ...ication performance 4 2 1 Features 4 2 2 Refrigerant circuit 5 2 3 Unit outlook 5 2 4 Specifications 6 2 5 Performance diagram 8 2 6 Wiring diagram 16 2 7 Installation 18 2 8 Trial run 26 2 9 Maintena...

Page 3: ...385 220 240V 50Hz 1Ph LRSJ 80 NYN1 66 75 1015 705 385 220 240V 50Hz 1Ph LRSJ 120 NYN1 75 85 1050 855 315 220 240V 50Hz 1Ph LRSJ 140 NYN1 75 85 1050 855 315 220 240V 50Hz 1Ph 1 2 External appearance 1...

Page 4: ...ge fire explosion etc Environmental protection Environment friendly refrigerant R410A is used No discharge of poisonous gas No pollution to atmosphere and environment Easy operation and automatic cont...

Page 5: ...RSJ 140 NYN1 Evaporator Copper tube and aluminum fin type heat exchanger Titanium tube heat exchanger Titanium tube heat exchanger is use for heat exchange between refrigerant and water Fan Axial fan...

Page 6: ...5 705 385 1050 855 315 1050 855 315 Packing W H D mm 1095 840 445 1095 840 445 1160 980 410 1160 980 410 Net gross weight kg 64 73 66 75 75 85 75 85 Outdoor noise level dB A 58 58 58 58 Refrigerant ty...

Page 7: ...766 792 Number of circuits 5 5 8 8 Water pipeline Water inlet pipe 50 50 50 50 Water outlet pipe 50 50 50 50 Water circulating pipe 25 25 25 25 Max pressure MPa 0 4 0 4 0 4 0 4 The volume flow of wate...

Page 8: ...mestic Pool Type Technical Manual 2 5 Performance diagram 2 5 1 Unit capacity and energy efficiency diagram in heating mode Model LRSJ 60 NYN1 Notes The test conditions inlet water temperature is 27 o...

Page 9: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 9 Model LRSJ 80 NYN1 Notes The test conditions inlet water temperature is 27 outlet water temperature is 29...

Page 10: ...TCAC RTSM 20150203 Tadiran Domestic Pool Type Technical Manual Model LRSJ 120 NYN1 Notes The test conditions inlet water temperature is 27 outlet water temperature is 29...

Page 11: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 11 Model LRSJ 140 NYN1 Notes The test conditions inlet water temperature is 27 outlet water temperature is 29...

Page 12: ...03 Tadiran Domestic Pool Type Technical Manual 2 5 2 Unit capacity and energy efficiency diagram in cooling mode Model LRSJ 60 NYN1 Notes The test conditions inlet water temperature is 27 water flow v...

Page 13: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 13 Model LRSJ 80 NYN1 Notes The test conditions inlet water temperature is 27 water flow volume is 3 5m3 h...

Page 14: ...TCAC RTSM 20150203 Tadiran Domestic Pool Type Technical Manual Model LRSJ 120 NYN1 Notes The test conditions inlet water temperature is 27 water flow volume is 5 0m3 h...

Page 15: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 15 Model LRSJ 140 NYN1 Notes The test conditions inlet water temperature is 27 water flow volume is5 8m3 h...

Page 16: ...TCAC RTSM 20150203 Tadiran Domestic Pool Type Technical Manual 2 6 Wiring diagram Model LRSJ 60 NYN1 LRSJ 80 NYN1...

Page 17: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 17 Model LRSJ 120 NYN1 LRSJ 140 NYN1...

Page 18: ...tal Do not install the heat pump close to inflammable gas source Do not install the heat pump close to a road or path to protect the appliance against mud splashing Avoid places that are subject to st...

Page 19: ...estic Pool Type Technical Manual TCAC RTSM 20150203 19 Space of foot screw bolts unit mm Model A B C D E F LRSJ 60 NYN1 LRSJ 80 NYN1 610 390 170 1015 385 705 LRSJ 120 NYN1 LRSJ 140 NYN1 590 333 165 10...

Page 20: ...efore operation please confirm that the specifications of connective pipes are correct and thermal insulation layer have been wrapped on pipes It requires that all pipes have been sealed up and no wat...

Page 21: ...h 5 8m3 h Water treatment In order to use our appliances under the best conditions the following parameters must be respected Maximum concentration of free chlorine is 2 5 mg L Maximum concentration...

Page 22: ...it is not equipped with power cord User could select power cable by reference to power supply specifications Shield wire must be employed for signal wire Select the power supply capacity and wire size...

Page 23: ...of the unit for the security reason it is required that a leakage protector should be installed in the external electric control box of the unit according to the requirement on the above diagram Cabl...

Page 24: ...d out The photo of main control board PCB I O Ports description Code Part name Code Part name N C No connect Tp Temperature sensor of compressor air exhaust Tout Outlet water temperature sensor Pro_H...

Page 25: ...Tadiran Domestic Pool Type Technical Manual TCAC RTSM 20150203 25...

Page 26: ...ally in the heating mode Whether the outlet water temperature is normal Whether there is vibration or abnormal sound when operating Whether there is refrigerant leakage 2 9 Maintenance Before leave th...

Page 27: ...is broken Whether the protection device works Operation lamp is lightened Whether it is the time set Operation lamp is lightened Inefficient heating Whether the inlet and outlet of heat pump units is...

Page 28: ...temperature sensor is correctly connected to the motherboard Check whether the signal of Tp sensor is in strong electromagnetic interference P0 System high pressure protection 4 4MPa active 3 2MPa ina...

Page 29: ...e fans are restarted This cloud is evacuated to the back of the unit Operation condition of the heat pump water heater For proper using of water heater please operate at the outdoor temperature 7 38 W...

Page 30: ...bout RCCB Outdoor unit must use RCCB be install a RCCB between in user power supply and the outdoor unit In case the unit cannot act but not attribute to power failure please check these RCCB switches...

Page 31: ...rature and blank when screen protection Codes are showed at the malfunction or protection time ALARM indicator It will flashing at the malfunction or protection time Names of keys on the wire controll...

Page 32: ...L TEMP 2 Mode Selection The unit is enhanced with three operation modes Cool Mode Heat Mode and Pump Mode Cool Mode The unit cools down swimming pool water by compressor drive according to heat pump p...

Page 33: ...ating 4 Pump 8 standby 4th Fan speed 0 OFF 1 Low 2 High 5th Ambient temperature Value of T4 6th Compressor discharge temperature Value of Tp 7th Pipe temperature Value of T3 8th Inlet water temperatur...

Page 34: ...68355 74 1 43498 114 0 42304 5 46 5725 35 6 40021 75 1 38703 115 0 41164 4 44 36 6 13059 76 1 34105 116 0 4006 3 41 5878 37 5 87359 77 1 29078 117 0 38991 2 39 8239 38 5 62961 78 1 25423 118 0 37956 1...

Page 35: ...7 261 4 33 38 89 73 8 643 113 2 559 6 247 8 34 37 3 74 8 358 114 2 489 5 234 9 35 35 78 75 8 084 115 2 422 4 222 8 36 34 32 76 7 82 116 2 357 3 211 4 37 32 94 77 7 566 117 2 294 2 200 7 38 31 62 78 7...

Reviews: