T200M Series Installation Manual - Aeonix
Diagnostics and Troubleshooting
73
Overview
11
11
Diagnostics and Troubleshooting
................................................................................................................
Overview
This section describes:
Diagnostics and Troubleshooting, page 73
Problems During Installation, page 76
Failure Messages During Installation, page 77
................................................................................................................
Diagnostics and Troubleshooting
Table 17 T207M/NP,
T208M/BL, T207M and
T208M Diagnostics and
Troubleshooting
Symptom
Meaning
Required Action
Your display panel is
blank AND the buttons
and message lamp are
OFF.
Your phone. is not powered.
Check the power
connection to your phone.
Your display panel is
blank AND the buttons
and message lamp are
ON.
The phone is initializing.
No action required.
The organizational logo
appears on your display
panel along with a
The phone is initializing.
No action required.
The following message
appears:
No physical link
The connection to the LAN or
PC is faulty.
Check the connection to the
LAN and to the PC
The following message
appears:
IP Address not
legal
A static IP address was
entered that was not legal.
Do one of the following:
Verify that the IP
address is correct.
Configure the phone to
DHCP.