background image

Summary of Contents for TAD TAD-M600

Page 1: ......

Page 2: ...y operating the equipment on thick carpet or a bed D3 4 2 1 7b_A_En Operating Environment Operating environment temperature and humidity 5 C to 35 C 41 F to 95 F less than 85 RH cooling vents not blocked Do not install this unit in a poorly ventilated area or in locations exposed to high humidity or direct sunlight or strong artificial light D3 4 2 1 7c _A1_En WARNING This equipment is not waterpr...

Page 3: ...r make a knot in the cord or tie it with other cords The power cords should be routed such that they are not likely to be stepped on A damaged power cord can cause a fire or give you an electrical shock Check the power cord once in a while When you find it damaged ask your dealer for a replacement S002 _En If you want to dispose this product do not mix it with general household waste There is a se...

Page 4: ... 5 Features 5 BEFORE YOU START 6 Checking what s in the box 6 Controls and displays 6 INSTALLATION AND CONNECTIONS 7 Installation 7 How to install 7 Adjusting the spike height 8 Connecting your equipment 9 Connecting to the Pre Amplifier 9 Bi wire connection 10 Connecting to the speaker system 11 Connecting the power cord 12 TO BEGIN PLAYBACK 13 Before turning on the power 13 Playback 13 Protectio...

Page 5: ...ructure for the spikes and a 10 mm thick aluminum vibration damper between the transformer and chassis Low center of gravity Lower Weight Balanced Frame The monocoque chassis is constructed from 35 kg of cast iron in order to produce a massive and stable foundation In addition the TAD M600 has adopted a wide tread chassis structure by locating the legs on the outer edges of its body further loweri...

Page 6: ...will light red during start up or if there is a malfunction The indicator will light yellow when the unit is ready to operate If the power indicator light turns from yellow to red turn off the power and refer to Protection circuit on page 13 If the trouble is still not resolved ask your dealer Power switch 222 Press to turn the power on off Flip the switch to the right to turn the power on flip th...

Page 7: ...ns while operating Failure to do so could cause the unit to malfunction through abnormal heating TAD M600 Leave 60 cm open CAUTION As the TAD M600 emits a large amount of heat do not place this unit on top of soft surfaces such as carpeting or cushions or in small spaces How to install In order to improve sound quality and prevent damage to the floor or other installation surface please use the ac...

Page 8: ...on the rear right leg of the TAD M600 as indicated below 111 INPUT BALANCED SPEAKERS CLASS 2 WIRING A B Insert the provided hexagon wrench and adjust the spike height so that the TAD M600 does not wobble 222 Replace the cover removed in step 1 333 ...

Page 9: ...onnections When connecting other components make sure to turn the power off and unplug the other components before connecting INPUT BALANCED SPEAKERS A B TAD M600 To speaker terminal Speaker To balance output terminal Pre Amplifier Connecting to the Pre Amplifier Connect a balance cable with an XLR plug sold separately to the INPUT BALANCED terminal of the TAD M600 and the Pre Amplifier s balance ...

Page 10: ...00 TAD M600 INPUT BALANCED SPEAKERS A B INPUT BALANCED SPEAKERS A B High Low High Low To balance output terminal To balance output terminal Pre Amplifier Rear side of bi wiring compliant speakers Rear side of bi wiring compliant speakers Note SPEAKERS A terminals and SPEAKERS B terminals produce the same output High and Low connectors can be made to either terminals A or B CAUTION When using bi wi...

Page 11: ...o cut off as a safety measure These speaker terminals carry HAZARDOUS LIVE voltage To prevent the risk of electric shock when connecting or disconnecting the speaker cables disconnect the power cord before touching any uninsulated parts How to connect the speaker system Connect the positive terminal of the speaker system to the positive terminal of the TAD M600 Connect the negative terminal of the...

Page 12: ...ctor of the TAD M600 111 Connect the power plug to a power outlet AC 230 V 222 INPUT BALANCED SPEAKERS A B 1 2 TAD M600 Power outlet Power cord 2 pin supplied CAUTION As the TAD M600 has high power consumption be sure to connect the plug to a power outlet providing sufficient electrical capacity Connecting to a power outlet with low electrical capacity could result in abnormal heating of the plug ...

Page 13: ...ided with a built in automatic protection circuit to prevent electrical damage to the amplifier and speakers When the protection circuit operates the power indicator will light red and no sound will be produced from the speakers The protection circuit may operate in the following circumstances When power is first turned ON In order to silence potential noise during startup the muting circuit opera...

Page 14: ...sk your dealer Symptom Possible cause Remedy Power does not turn on The power plug is not connected to the power outlet The power cord is not connected to the AC IN connector of the TAD M600 Firmly plug in the power cord to the power outlet Firmly plug in the power cord to the AC IN connector No sound output The speaker cable is disconnected or is not connected correctly The terminal or the speake...

Page 15: ...e Specifications and the design are subject to possible modifications without notice due to improvements To ensure long product life avoid installing this unit in the following locations Locations exposed to direct sunlight Humid or poorly ventilated areas Areas of extreme temperatures Areas with vibration Dusty or smoky areas Areas exposed to grease fumes steam or heat such as a kitchen Maintenan...

Page 16: ...ient pas à la prise secteur à utiliser la fiche doit être remplacée par une appropriée Ce remplacement et la fixation d une fiche secteur sur le cordon d alimentation de cet appareil doivent être effectués par un personnel de service qualifié En cas de branchement sur une prise secteur la fiche de coupure peut provoquer une sérieuse décharge électrique Assurez vous qu elle est éliminée correctemen...

Page 17: ... noeud avec le câble ou l attacher à d autres câbles Les câbles d alimentation doivent être posés de façon à ne pas être écrasés Un câble abîmé peut provoquer un risque d incendie ou un choc électrique Vérifier le câble d alimentation de temps en temps Si ce câble est endommagé contacter son revendeur à propos de son remplacement S002 _A1_Fr Si vous souhaitez vous débarrasser de cet appareil ne le...

Page 18: ...ecker der geeigneten Ausführung ausgewechselt werden Ein derartiger Austausch des Netzsteckers muss vom Kundendienstpersonal vorgenommen werden Wenn der vom Netzkabel abgeschnittene ursprüngliche Netzstecker in eine Netzsteckdose eingesteckt wird besteht akute Stromschlaggefahr Daher ist unbedingt dafür zu sorgen dass der abgeschnittene Netzstecker sofort vorschriftsmäßig entsorgt wird Vor einem l...

Page 19: ...s niemand darauf tritt Ein beschädigtes Netzkabel kann einen Brand oder elektrischen Schlag verursachen Prüfen Sie das Netzkabel von Zeit zu Zeit Falls eine Beschädigung des Netzkabels festgestellt wird wenden Sie sich bitte an Ihren Fachhändler um ein Ersatzkabel zu erwerben S002 _A1_De Mischen Sie dieses Produkt wenn Sie es entsorgen wollen nicht mit gewöhnlichen Haushaltsabfällen Es gibt ein ge...

Page 20: ...adatta allo scopo La sostituzione della spina del cavo di alimentazione deve essere effettuata solamente da personale di servizio qualificato Dopo la sostituzione la vecchia spina tagliata dal cavo di alimentazione deve essere adeguatamente eliminata per evitare possibili scosse o folgorazioni dovute all accidentale inserimento della spina stessa in una presa di corrente sotto tensione Se si pensa...

Page 21: ...e cortocircuiti o scosse elettriche Non collocate l unità oppure dei mobili sopra il filo di alimentazione e controllate che lo stesso non sia premuto Non annodate mai il filo di alimentazione nè collegatelo con altri fili I fili di alimentazione devono essere collocati in tal modo che non saranno calpestati Un filo di alimentazione danneggiato potrebbe causare incendi o scosse elettriche Controll...

Page 22: ...e adapte apropiadamente El reemplazo y montaje de una clavija del cable de alimentación de CA sólo deberá realizarlos personal de servicio técnico cualificado Si se enchufa la clavija cortada a una toma de corriente de CA puede causar fuertes descargas eléctricas Asegúrese de que se tira de la forma apropiada después de haberla extraído El aparato deberá desconectarse desenchufando la clavija de l...

Page 23: ... de no hacer nudos en el cable ni de unirlo a otros cables Los cables de alimentación deberán ser dispuestos de tal forma que la probabilidad de que sean pisados sea mínima Una cable de alimentación dañado podrá causar incendios o descargas eléctricas Revise periódicamente el estado del cable de alimentación Cuando el cable esté dañado pida un reemplazo a su distribuidor S002 _A1_Es Si desea desha...

Page 24: ...d in Japan TECHNICAL AUDIO DEVICES LABORATORIES INC 4 15 3 Nishi Shinjuku Shinjuku ku Tokyo 160 0023 Japan http tad labs com Published by Pioneer Corporation Copyright 2009 TECHNICAL AUDIO DEVICES LABORATORIES INC All rights reserved ...

Reviews: