Tactical Controls Limited
Power Enclosure Assembly Instruction Manual
Specification
Mains distribution
3 off 240Vac outlets.
DC supplies
+24V at 4A.
+12V at 20A with remote sense and local setting.
-12V at 1.5A.
+5V at 8A with local setting.
-5V at 1.5A.
Connections via 2 off 9-way chassis mounted sockets and +24V to
comms control.
Dimmer control
Computer interface via DIN 5-way audio socket.
Dimmer output via DIN-rail mounted terminal blocks.
For detail, see 150LD instruction manual.
Vacuum control
Position sensor, limit switch and 24V via DIN-rail mounted terminal
blocks; air intake via 55mm outside diameter pipe.
For detail, see 305MC instruction manual.
Reliability
MTBF of not less than 1000 hours.
Supply
215 to 2/-5%, 50Hz +/-1%
Temperature
0 to 50 ºC operating; -20 to 65 ºC storage
Dimensions
700mm(H) x 700mm(W) x 300mm(D)
Mounting positions
Wall mounted on fixing centres 590 x 600mm
or free floor standing on 4 rubber feet
Weight
65Kg max.
References
"Critical Item Design Specification (CIDS) for the Power Cabinet (PCAB) HWCI of the
Power and Air (PAIR) HWCI of the Infantry Weapons Training Simulator (IWTS) Segment",
Thomson Training & Simulation Limited, Generic Weapons Training Simulator, Document
Number: 46 486 649-532B, 1994.
"Schematic diagrams for the power cabinet", Thomson Training & Simulation Limited,
drawing no: 46 486 649-197, June 1994, Rev.A.
305MC Instruction Manual
Mitsubishi General Purpose Inverter FREQROL-U120S-ER Instruction Manual
150LD Instruction Manual
pea\im
Page 11
16 March 1998
Issue 4.0