Tactical Controls 72TS Instruction Manual Download Page 11

Tactical Controls Limited

72TS Train Number Box

Instruction Manual

Dimensional drawing (base unit)

72TSTNB Instruction Manual.doc

Page 11

2 March 2007

Issue 1.0

Summary of Contents for 72TS

Page 1: ...f may not be reproduced in any form without written permission of the publishers The information in this document is subject to change without notice and should not be construed as a commitment by Tac...

Page 2: ...4 Installation 5 Protection 5 Connection diagram 6 Connection terminals base unit 7 Connection terminals remote unit 8 Layout diagram base unit 9 Layout diagram remote unit 10 Dimensional drawing bas...

Page 3: ...urtain ACC When the measured temperature is lower than the setpoint temperature the output will cycle between its minimum and maximum output settings All user adjustments are by means of front panel p...

Page 4: ...s standard Control output Opto triac outputs are used for the control of heater output The rating is 3 phase 3 wire 415Vac 12KW max Relay outputs are used for the control of the fan speed high medium...

Page 5: ...is connected to a 6 way connector marked N Lo Md Hi The sensor input air sensor is connected to a 2 way connector marked AIR on the base unit The sensor is not polarity sensitive The BMS control logic...

Page 6: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Connection diagram 72TSTNB Instruction Manual doc Page 6 2 March 2007 Issue 1 0...

Page 7: ...n medium speed Hi Fan high speed BMS BMS control logic normally closed volt free contact BMS BMS control logic normally closed volt free contact AIR Air sensor non polarised AIR Air sensor non polaris...

Page 8: ...Box Instruction Manual Connection terminals remote unit Terminal Description 7V Supply from base unit 0V Supply from base unit B RS485 Comms to base unit A RS485 Comms to base unit 72TSTNB Instructio...

Page 9: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Layout diagram base unit 72TSTNB Instruction Manual doc Page 9 2 March 2007 Issue 1 0...

Page 10: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Layout diagram remote unit 72TSTNB Instruction Manual doc Page 10 2 March 2007 Issue 1 0...

Page 11: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Dimensional drawing base unit 72TSTNB Instruction Manual doc Page 11 2 March 2007 Issue 1 0...

Page 12: ...50 90 60 C 2 Heatsink alarm setting 50 90 65 C 3 Minimum Power setting 0 99 0 The default display on the remote unit is the air sensor temperature Air temperature t This will change to alarm display i...

Page 13: ...lifted by several degrees depending on the Fan setting For example when the setpoint is 20 and the fan is set at high speed 3 the control setpoint will be 20 8 28 Internal setpoint lift due to air ch...

Page 14: ...e heatsink sensor detects the temperature of the heatsink above 65 C Heatsink sensor failure Code 16 this is triggered when the heatsink sensor is open circuit typically when the heatsink sensor is br...

Page 15: ...the heater switching devices Fan Output 3 off Relay for High Medium and Low Fan setting 3A max 240Vac Display Three 7 segment LED red for parameter display Push buttons 3 positive feedback tactile pus...

Page 16: ...ith 415V supply and 12KW load maximum or ACC 6 00 is an Air Curtain controller with 240V supply and 6KW load maximum Ambirad Part numbers Remote Unit 900306 Base Unit 6KW to be confirmed Base Unit 9KW...