Tactic Any Link Mounting Instructions Download Page 2

WARNING! Do NOT turn the Spektrum Tx 
power switch to the ON position at any time 
while operating the model! 

This will cause 

AnyLink to stop sending signals to the Tactic Rx, resulting 
in a loss of control of the model. The Spektrum Tx power 
switch should ALWAYS remain in the OFF position when 
controlling a model with AnyLink. Make sure all connections 
between AnyLink and the Tx are solid physically and cannot 
easily become dislodged at any time.

C. Insert the power connector into AnyLink’s INPUT jack. 
Confi rm that AnyLink’s LED turns on at this time. 

IMPORTANT:

 Make sure the LiFe battery is fully 

charged before use! Failure to do so could result 
in AnyLink losing power during fl ight, causing 
signal loss and crash of the model.

AnyLink should now be transmitting a signal, and ready 
to control the Tactic SLT receiver inside the model. After 
reading all remaining instructions below, return to the 
ANYLINK OPERATION section of the instruction manual 
included with the AnyLink SLT 2.4GHz Radio Adapter.

REMOVING POWER

REMOVING POWER

When a fl ying session has ended, with the model on the 
ground and power safely removed from the model, power 
must also be removed from the AnyLink 

and

 the Spektrum 

transmitter. Failure to do so will drain this Power Adapter’s 
LiFe battery and battery inside the Spektrum transmitter.

1. Disconnect the power connector from AnyLink’s INPUT 
jack.

2. Disconnect the Power Adapter’s signal connector from 
the Tx trainer jack. This will turn off  the logic circuit inside 
the Spektrum Tx.

IMPORTANT!

 ALWAYS make sure the protective 

boot covers this Power Adapter’s signal 
connector any time AnyLink is not in use.

TROUBLESHOOTING

TROUBLESHOOTING

Short flight time:

LiFe battery is weak and must be re-charged.

AnyLink LED will not light:

Power plug not properly connected to AnyLink. 
Re-check connection. Battery is weak and must be 
recharged.

Spektrum Tx will not function:

Signal plug not properly connected to Tx. Re-check 
connection.

Neither Rx nor servos function:

Rx not properly bound to AnyLink. See AnyLink 
instructions for details. Rx battery weak, or not 
connected properly. Re-charge battery and re-check 
all connections at Rx.

LiFe BATTERY SAFETY & HANDLING

LiFe BATTERY SAFETY & HANDLING

LiFe batteries must be handled diff erently than NiCd, NiMH, 
and LiPo batteries. Failure to follow these instructions 
can quickly result in severe, permanent damage to the 
battery. Tactic will not be held responsible for any and all 
incidental damages that may result from improper use 
of this adapter. Before and after every use of your LiFe 
battery, inspect the pack carefully to ensure no physical 
damage is evident, such as swelling, splitting or torn outer 
heat shrink wrapper, or loose plugs and wires. Such signs 
can often indicate a problem exists with the battery that 
could lead to failure. 

  NEVER charge LiFe batteries with a non-LiFe compatible 

charger.

  NEVER charge this LiFe battery at currents or voltages 

which exceed the ratings listed above.

  NEVER leave a LiFe battery unattended at ANY TIME 

while being charged or discharged.

  NEVER allow this Power Adapter’s signal plug to make 

contact with metal wristwatches, bracelets, or rings, which 
can cause accidental short circuit conditions and possible 
personal injury. Always place the boot over this plug when 
not in use.

  Do not continue charging a LiFe battery if the charger 

fails to recognize full charge. Overheating, swelling, or 
emission of smoke of LiFe cells indicates that a problem 
exists. Disconnect the batteries from the charger 
immediately and placed in safe location to cool.

  Do not allow LiFe batteries to freeze or exceed 140°F 

[60°C] at any time. Do not reuse a LiFe battery that you 
suspect has been damaged in any way.