WARNING! Do NOT turn the Spektrum Tx
power switch to the ON position at any time
while operating the model!
This will cause
AnyLink to stop sending signals to the Tactic Rx, resulting
in a loss of control of the model. The Spektrum Tx power
switch should ALWAYS remain in the OFF position when
controlling a model with AnyLink. Make sure all connections
between AnyLink and the Tx are solid physically and cannot
easily become dislodged at any time.
C. Insert the power connector into AnyLink’s INPUT jack.
Confi rm that AnyLink’s LED turns on at this time.
IMPORTANT:
Make sure the LiFe battery is fully
charged before use! Failure to do so could result
in AnyLink losing power during fl ight, causing
signal loss and crash of the model.
AnyLink should now be transmitting a signal, and ready
to control the Tactic SLT receiver inside the model. After
reading all remaining instructions below, return to the
ANYLINK OPERATION section of the instruction manual
included with the AnyLink SLT 2.4GHz Radio Adapter.
REMOVING POWER
REMOVING POWER
When a fl ying session has ended, with the model on the
ground and power safely removed from the model, power
must also be removed from the AnyLink
and
the Spektrum
transmitter. Failure to do so will drain this Power Adapter’s
LiFe battery and battery inside the Spektrum transmitter.
1. Disconnect the power connector from AnyLink’s INPUT
jack.
2. Disconnect the Power Adapter’s signal connector from
the Tx trainer jack. This will turn off the logic circuit inside
the Spektrum Tx.
IMPORTANT!
ALWAYS make sure the protective
boot covers this Power Adapter’s signal
connector any time AnyLink is not in use.
TROUBLESHOOTING
TROUBLESHOOTING
Short flight time:
LiFe battery is weak and must be re-charged.
AnyLink LED will not light:
Power plug not properly connected to AnyLink.
Re-check connection. Battery is weak and must be
recharged.
Spektrum Tx will not function:
Signal plug not properly connected to Tx. Re-check
connection.
Neither Rx nor servos function:
Rx not properly bound to AnyLink. See AnyLink
instructions for details. Rx battery weak, or not
connected properly. Re-charge battery and re-check
all connections at Rx.
LiFe BATTERY SAFETY & HANDLING
LiFe BATTERY SAFETY & HANDLING
LiFe batteries must be handled diff erently than NiCd, NiMH,
and LiPo batteries. Failure to follow these instructions
can quickly result in severe, permanent damage to the
battery. Tactic will not be held responsible for any and all
incidental damages that may result from improper use
of this adapter. Before and after every use of your LiFe
battery, inspect the pack carefully to ensure no physical
damage is evident, such as swelling, splitting or torn outer
heat shrink wrapper, or loose plugs and wires. Such signs
can often indicate a problem exists with the battery that
could lead to failure.
NEVER charge LiFe batteries with a non-LiFe compatible
charger.
NEVER charge this LiFe battery at currents or voltages
which exceed the ratings listed above.
NEVER leave a LiFe battery unattended at ANY TIME
while being charged or discharged.
NEVER allow this Power Adapter’s signal plug to make
contact with metal wristwatches, bracelets, or rings, which
can cause accidental short circuit conditions and possible
personal injury. Always place the boot over this plug when
not in use.
Do not continue charging a LiFe battery if the charger
fails to recognize full charge. Overheating, swelling, or
emission of smoke of LiFe cells indicates that a problem
exists. Disconnect the batteries from the charger
immediately and placed in safe location to cool.
Do not allow LiFe batteries to freeze or exceed 140°F
[60°C] at any time. Do not reuse a LiFe battery that you
suspect has been damaged in any way.
Summary of Contents for Any Link