If the lines are not ready, the domestic hot water
module can be filled using provisional lines by means
of the fill and drain cocks (
fresh water station and checking for leak-tightness’
5.3
Connecting pipes
5.3.1
Connecting lines
Observe the hydraulic diagram (
instructions for cascading the stations.
Personnel:
n
Heating and sanitary technician
Tool:
n
Adjustable spanner
Prerequisite:
n
The fresh hot water station was prepared in accordance with
Chapter 5.2 ‘Prerequisites for installation ’ on page
1.
Connect the main supply line for drinking water to the connec-
tion for the main supply line for drinking water (Fig.
tighten it by hand.
2.
Connect the hot water line to the connection for drinking water
3.
Connect the main supply line for the heater flow line to the pri-
mary connection for the heat supply flow line (Fig.
tighten it by hand.
4.
Connect the main supply line for the heater return line to the
tank integration at the bottom (Fig.
hand.
5.
If installed, connect the circulation line to the connection for
6.
If installed, connect the two-zone stratifier line to the connec-
tion for the two-zone stratifier (Fig.
hand.
Connecting the domestic hot water
module provisionally
Cascading option
Connecting lines
Fig.
23:
Connecting cocks
1 Primary connection for the heat
supply flow line
2 Tank integration, bottom
3 Connection of integrated circula-
tion (optional)
TACOTHERM FRESH PETA 2 / PETA 2 X
Assembly and installation
V02.2020 11/2020
Item no. 215747
EA no. 1329
Operating instructions
35