Radio frequency (RF) thermostat (868
MHz) specially designed for water floor
heating systems. Each thermostat pos-
sesses with an own personal code. Thus
a clear allocation to the receiver is en-
sured.
-
Equipped with a LCD display to select
Comfort (
), Night reduction (
) or Off
mode.
-
Temperature indication for desired value
and actual value (room temperature)
-
This thermostat can be used only with the
1 channel receiver or with the radio re-
ceiver (TIMER) of the manufacturer.
START UP
Use the switch on the right side of the ther-
mostat to power on or power off the heating.
Be careful! In mode OFF, your installation can
freeze.
The setting temperatures are kept in memory
indefinitely.
NOVASTAT RF DIGITAL (RT-RFD)
USER GUIDE
GB
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
Measured temperature precision
0.1°C (or 0.2°F)
Operating temperature
0°C - 50°C (or 32°F
– 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step
(or 41°F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation (adjustable see installation
menu) Cycle: 15 minutes or
Static differential 0.3°K
Anti-short cycle: 2min in OFF, 2min in ON.
Electrical Protection
Class II - IP30
Power Supply
Battery operated life
2 x 1,5V (AAA) ALKALINE type
~ 2 years
Radio frequency
868 MHz, <10mW.
CE Directives
Your product has been designed in
conformity with the European Direc-
tives.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
RADIO CONFIGURATION MODE
-
Position that/ those radio room thermostat/s in the proximity of the radio
Receiver (TIMER or 1 channel receiver)
-
For the allocation of the RF thermostat to a receiver, you must put the receiver in “RF init”
mode (please refer to the receiver leaflet).
-
After you just h
ave to press “
Ok
” key during 5 sec. If the display ( “rF “)
is indicated, the thermostat sends its configuration address by radio signal.
-
When the receiver is configured, press “
Ok
” key to return to user menu. The desired
room temperature can be adjusted.
Use
“
Ok
” key to change the mode in the
Operating mode menu
COMFORT operating mode:
Force comfort temperature operation indefi-
nitely. By pr/- keys the comfort tem-
perature starts to blink and can be adjusted.
The measured temperature reappears
after a few seconds.
REDUCTION operating mode:
Force reduced temperature operation indefi-
nitely. By pr/- keys the comfort tem-
perature starts to blink and can be adjusted.
The measured temperature reappears after
a few seconds.
DISPLAY
Press the (
OK)
key during 5 seconds. The display switches at first in the radio initialization mode "rF".
Then use
+
or
-
keys to select and adjust the installation parameter. Press
OK
to toggle the parameter setting or edit the value. If the
value starts to blink you can use
+
/
-
keys to adjust this value. Once you have adjusted the value press
OK
to validate
this parameter value.
When you have finished, use
+
or
-
keys to go to ‘rF’ display and then press
OK
key to exit installa-
tion parameter menu. Without an input, the display switches after 30 seconds in the normal operation mode. The
changed parameters thereby are saved. Press + & - keys at the same time to reset this value to the factory default value.
rF :
Radio configuration mode (see section). Press
OK
to return to normal operation mode.
J0 :
°C / °F temperature display selection
J1 :
“Hot” / “Cold” regulation mode. Select Hot for a Heater system, select Cold for a Cooling system
J5 :
Select
“PMP” to perform an 1 minute exercise everyday (if installation inactive during a day)
J6 :
Air or Floor temperature regulation selection. (If no Floor sensor, regulation will use Air sensor)
Ao :
Air sensor offset adjustment (default: no offset). Display measured Air sensor value
Fo :
Floor sensor offset adjustment (default: no offset). Display measured Floor sensor value
FL :
Floor temperature LOW limitation (default: 5°C/41°F), effective only if floor sensor present
FH :
Floor temperature HIGH limitation (default: 28°C/82°F) , effective only if floor sensor present
J7 :
“rEG” (Proportional Integral) or “HYs” (0.3°K Hysteretic) regulation type selection
Cy :
Proportional Integral regulation time cycle value in minutes (default: 15 minutes cycle)
On:
Anti short cycle time relay ON:
2mn
: Minimum time ON
Of:
Anti short cycle time relay OFF:
2mn
: Minimum time Off
bp :
Proportional Integral regulation band amplitude value in degrees °C/°F (default: 2.0°C/3.6°F)
Cp :
compensation value in °C/°F (default: 2.0°C/3.6°F) this parameter must be adjusted by a professional.
CLr :
Press
OK
key during 5s to reset all the WFHT LCD parameters to factory defaults
End :
Press
OK
key to exit installation parameter menu and return to normal operation
* (Default parameters are underlined.)
INSTALLATION PARAMETERS MENUS
1:
Operating mode menu.
2:
Heating indication.
3:
Cooling indication.
4:
Batteries weak
5:
If symbol is displayed the measured temperature
is shown (position 6)
6:
Measured temperature or set temperature.
7:
°C or °F indication.
8:
Title for installation Parameters (rF,
J0,CLr…)
Switch on and switch off the thermostat