![Taconova NOVASTAT RF BASIC User Manual Download Page 4](http://html1.mh-extra.com/html/taconova/novastat-rf-basic/novastat-rf-basic_user-manual_3163324004.webp)
RF basic thermostat
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
-
Radio frequency (RF) thermostat (868 MHz) specially designed for water floor
heating systems.
-
Each thermostat possesses an own personal code. Thus a clear allocation to
the receiver is ensured.
-
Equipped with a switch to select Comfort (
), Night reduction (
) or Off mode.
-
This thermostat can be used only with the 1 channel receiver or with the radio
receiver (TIMER) of the manufacturer.
-
-
LED INDICATOR
Red:
- Heating indication (set point transmission)
Red Blinking:
-
1 second cycle, Low batteries indication. (please change)
- Fast blinking: sensor default
Green blinking:
- Radio transmission (1 flash by transmission)
Room
setting.
Select
mode.
LED Indicator.
Measured temperature preci-
sion
0.1°C (or 0.2°F)
Operating temperature
0°C - 50°C (or 32°F
– 122°F)
Setting temperature range
5°C
– 30°C (or 41°F - 86°F)
Regulation characteristics
Proportional band 15min for 2°K
Electrical Protection
Class II - IP30
Power Supply
Battery operated life
2 x 1,5V (AAA) ALKALINE
~ 2 years
Radio frequency
868 MHz, <10mW.
CE Directives
Your product has been designed
in conformity with the European
Directives.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
RADIO CONFIGURATION MODE
-
Position that/ those radio room thermostat/s in the proximity of the radio
receiver (TIMER or 1 channel receiver)
-
Turn the thermostat switch in
Off
position. If several thermostats are as-
signed to a receiver, turn all mode switches in
Off
position.
-
To assign the RF thermostat with the receiver you must put the receiver
in “RF init” mode (please refer to the receiver leaflet).
-
After that, you just put the thermostat switch in Comfort
mode.
-
The thermostat sends its configuration address by radio signal. (The
thermostat LED blinks green)
-
After successful initialization switch the thermostat in Off position.
-
If several thermostats are assigned, this procedure is to be repeated with
all further thermostats.
-
Finally at the respective thermostat the desired room temperature and
the operating mode are adjusted.
NOVASTAT RF BASIC (RT-RF)
USER GUIDE
GB