background image

Application:

Taco

's  SmartPlus-e

  SmartPlug  Instant  Hot  Water  Control

®

  is 

designed  to  upgrade  any  hot  water  recirculation  system.  SmartPlug 

replaces inefficient timers and aquastats typically used in recirculation 

systems.  It  adds  intelligence  to  your  system  by  learning  when  hot 

water  is  used  in  the  home.  The  pipe-mounted  sensor  records  daily 

hot  water  usage  patterns  during  the  course  of  the  week.  Recorded 

data  is  used  to  automatically  run  the 

006e3

  at  the  same  times  the 

following week. So hot water is awlays available when it is needed. If 

usage pattern changes, the SmartPlug adjusts automatically.

Benefits:

• Easy to Install: 

Upgrades 

the SmartPlus-e 006e3 circulator 

to 

“Smart” operation.

• Comfort and Convenience:

 Hot water is available in seconds. No

rs or progra

time 

mming required.

• Efficiency:

 “Smart” mode maximizes hot water comfort and energy

savings.

• Reliability: 

The  SmartPlug,  when  combined  with 

the  006e3 

circulator,  provides  whisper  quiet  operation  and

 

industry  leading 

electronics for proven performance and dependability.

SmartPlug Control Options/Features:

 

“Smart” Mode:

  When set to Smart mode, the SmartPlug will run

 

in Pulse mode as described below for the first 7 days of operation.

 

During  the  first  7  days,  the  SmartPlug  monitors  and  records  the

 

home's  hot  water  usage  pattern.  For  the  following  7  days,  the

 

SmartPlug will use the preceding week's usage pattern to cycle

 

the 

006e3

 during the recorded hot water usage times.  This

 

process of 

recording  and  repeating  is  continuous,  and  automatically  adjusts 

the 

006e3

 ON times to match the household's

 

usage pattern.

• “Pulse” Mode: 

When set to Pulse mode, the SmartPlug will cycle

 

the 

006e3

 ON for 5 minutes, then OFF for 10 minutes to maintain 

hot  water  at  all  faucets  and  taps.  It  will  repeat  the  cycle  con-

tinuously.

• Vacation  Mode: 

After  36  hours  of  no  hot  water  usage,  the

 

SmartPlug  will  automatically  turn  the 

006e3

  OFF,  and  will  auto-

matically restart when hot water usage is detected.

• Exercise  Function: 

While  in  vacation  mode,  the  SmartPlug  will

 

cycle  the 

006e3

  ON  for  10  seconds  every  7  days  to  prevent

 

corrosion or scale buildup

SmartPlus-e SmartPlug Installation:

1. The  SmartPlus-e  SmartPlug  is  designed  for  use  with  Taco’s

SmartPlus-e 006e3 ECM High Efficiency Circulator.

2. Using  the  black  sensor  strap  provided,  attach  the  SmartPlug

sensor to the HOT water supply pipe from the water heater. 

USE

EXTREME  CAUTION  WHEN  INSTALLING  THE  TEMPERA-

TURE SENSOR ON THE HOT WATER SUPPLY PIPE AS PIPE

TEMPERATURE MAY BE EXTREMELY HOT. 

The sensor must

be  strapped  at  least  18"  away  from  the  hot  water  source  to

ensure proper sensor temperature readings. The "flat" side of the

sensor should be strapped directly to the hot water supply pipe

using the black sensor strap provided. If the supply pipe is insu-

lated  it  will  be  necessary  to  remove  the  insulation  at  the  point

where the sensor is installed to ensure accurate sensor readings.

3. Install  the  SmartPlug  temperature  sensor.  Connect  the  2  wire

leads on the temperature sensor to the green sensor connector

terminal block by loosening the 2 set screws.  Insert the 2 wire

leads from the temperature sensor into 

the terminal slots on the terminal con-

nector and tighten the 2 set screws. Be 

careful  not  to  over  tighten  screws  as 

you may damage the terminal con-

nector.  Once  the  temperature  sensor

wires are securely fastened, insert the

terminal  block  into  the  SmartPlug

receptacle labeled "SENSOR". NOTE: 

The SmartPlug sensor is provided with 

a 10' lead wire. Some installations may 

require a sensor lead wire in excess of 

10'. If the sensor lead length needs to 

be increased, standard "18 AWG"

gage wire and 2 wire nuts can be spliced into the temperature 

sensor lead wires to extend the overall length.

4. Plug the SmartPlug into a properly grounded 120V wall outlet.

LED’s will illuminate and a 10 second diagnostic check will begin.

5. Plug the 006e3 circulator 120V line cord into the SmartPlug. The

 

blue LED will illuminate on the face of the 006e3. 

NOTE: The

 

006e3 circulator is double insulated so does not need 

to be

 

grounded.

.

Setting the SmartPlus-e SmartPlug Operating Mode:

1. The SmartPlus-e SmartPlug has a MODE SELECT push button

on the bottom of the control that allows for 2 operating modes.

"Smart" or "Pulse" mode can be selected by pressing the MODE

SELECT button located on the lower right side of the control box.

To  set  the  mode,  make  sure  the  SmartPlug  is  plugged  into  a

properly  grounded  120V  outlet.  A  yellow  LED  labeled  "MODE"

on the face of the SmartPlug identifies the mode selected.

“Smart” Mode: Solid Yellow LED

“Pulse” Mode:  Blinking Yellow LED

Press and release the MODE SELECT button once to change 

the mode. 

2. The SmartPlug is also provided with a red "SENSOR" LED. If the

sensor  is  properly  installed  the  “SENSOR”  LED  will  not  illumi-

nate. If the red LED is flashing, refer to the troubleshooting sec-

tion  below.

3. Installation and mode selection are complete.
4. To ensure the SmartPlug is providing hot water properly, open a

hot water tap at the fixture furthest away from the hot water tank.

Use CAUTION as the water may be extremely hot.

Installing the SmartPlus-e SmartPlug Instant Hot Water Control®

WARNING:

 

For indoor use only.

A

Efficiency:

This

p

Insert the 2 wire

l

Be careful not

t

B

WARNING:  Risk  of  electrical  shock.  This  product  is  supplied

 

with  a  grounding  conductor  and  grounding-type  attachment

 

plug.  To  reduce  the  risk  of  shock,  be  certain  that  it  is 

connected

 

only  to  a  properly  grounded  grounding-type

 

receptacle.

WARNING: All local plumbing and electrical codes should be

 

followed when installing this product.

FCC  STATEMENT: 

This  equipment  has  been  tested  and  found  to  comply 

with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful inter-

ference  in  a  residential  installation.  This  equipment  generates,  uses  and  can 

radiate radio frequency energy and, if not installed and used in accordance with 

the  instructions,  may  cause  harmful  interference  to  radio  communications. 

However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular 

installation. If this equipment does cause harmful interference to radio or televi-

sion reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one or more of the 

follow-ing measures:
• Reorient or relocate the receiving antenna. • Increase the separation between

the equipment and receiver. • Connect the equipment into an outlet on a circuit 

different from that to which the receiver is connected.  • Consult the dealer or 

an experienced radio/TV technician for help.

2

Summary of Contents for SmartPlus-e

Page 1: ...tem components as shown in the piping diagram in Figure 4 3 Follow steps 3 through 6 listed under the Hot Water Return Line Option No 1 section Instruction Sheet 102 550 U S Patent 8 594 853 SUPERSEDES NEW EFFECTIVE February 27 2018 Plant ID 001 5008 Backflow Preventer Thermal Expansion Tank Temperature Sensor Fixtures Isolation Valve Union Isolation Valve Union Flow Check Valve Drain Valve Isolat...

Page 2: ...o over tighten screws as you may damage the terminal con nector Once the temperature sensor wires are securely fastened insert the terminal block into the SmartPlug receptacle labeled SENSOR NOTE The SmartPlug sensor is provided with a 10 lead wire Some installations may require a sensor lead wire in excess of 10 If the sensor lead length needs to be increased standard 18 AWG gage wire and 2 wire ...

Page 3: ...C A5 77 D E A D E B D E D A D0 B 39C AB Union Fitting Selection Guide 3 01 2 3 4 5 4 6 4 7 8 9 5 01 2 2 3 01 2 2 4 01 2 2 5 6 77 A7 4 4 8 4 4 8 4 6 4 0B C 8 4 5 DE F guid 7 8 4 7 7 8 G H I 6750 5 4 B A 4 J K1 4 8 4 5 7 L 8 65 4 4 7 7 B MIN LOW MED HIGH MAX Flow 0 2 1 3 6 5 4 7 8 9 10 11 12 13 14 Head 0 2 4 6 8 10 12 14 16 Q l s 0 8 0 6 0 4 0 2 0 0 H m 0 1 2 3 4 5 Q m 3 hr 0 0 0 5 1 0 1 5 2 0 2 5 3...

Page 4: ... NESS IS IN EFFECT ONLY FOR THE DURATION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARA GRAPH ABOVE THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR STATUTORY OR ANY OTHER WARRANTY OBLIGATION ON THE PART OF TACO TACO WILL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF ITS PRODUCTS OR ANY INCIDENTAL COSTS OF REMOVING OR R...

Reviews: