background image

Installation shall be in accordance with the manufacturer’s

instructions or warranty may be voided.

IMPORTANT

Operation of the Taco On Command without being plumbed into water lines may dam-
age the pump and void the warranty.

2. Tools you need:

• Pipe or crescent wrench

• Phillips and flat head screwdrivers

• Plier

• Drill and 

5

8

inch drill bit

• Wire strippers

3. Best location for the Taco On Command:

Typically, this would be at the fixture farthest away from the water heater, generally the
kitchen  or  master  bath  room.  If  your  hot  water  supply  runs  in  two  different  directions
from the water heater, you may need more than one Taco On Command.

PUMP POSITION

Pump  should  always  be  installed  in  a  horizontal
position  (as  shown)  with  On  Command  capacitor
box  facing  up  toward  the  sink.  Be  sure  arrow  on
pump casing is pointing from left to right (hot water
to cold water side) prior to connecting the flex lines.

Note: T’s and flex lines supplied by Taco provide
maximum  flow  and  performance.  Alternative
plumbing  parts  may  restrict  flow  and  delay  hot
water to fixtures.

WARNING: In the event the retaining screws have been pulled out of the hous-

ing, DO NOT replace them. Use of any other screw may short out
the stator windings, creating a risk of electrical shock.

WARNING: To avoid electrical shock, disconnect the power supply to the cir-

culator and the main electrical unit.

CAUTION: When  installing  electrical  connections,  do  not  apply  mechanical

loads  to  the  capacitor  box;  otherwise,  retaining  screws  may  be
pulled out of the housing, making circulator unusable.

PRE-INSTALLATION CHECKLIST

1. Taco On Command includes:

• Models 006-CT/006-CT-USK,

008-CT/008-CT-USK

• “00” Cartridge circulating pump

with built-in On Command
Electronics, power cord, Integral
Flow Check (IFC) and mounting
bracket

• Starter button
• Set of two (2) 

1

2

" plumbing

adapter tees (included with
“USK” models only)

• Set of two (2) 

1

2

" stainless steel

flex lines (included with “USK”
models only)

Summary of Contents for ON COMMAND 006-CT-USK

Page 1: ... parts available Patented Integral Flow Checks IFC are built into each On Command pump to prevent cold water from entering the hot water line State of the art electronics allow the On Command to accurately sense temperature and automatically shut off the pump to maximize comfort and energy savings On Command saves energy and water You can look forward to over 15 years of life expectancy with a Tac...

Page 2: ...e prior to connecting the flex lines Note T s and flex lines supplied by Taco provide maximum flow and performance Alternative plumbing parts may restrict flow and delay hot water to fixtures WARNING In the event the retaining screws have been pulled out of the hous ing DO NOT replace them Use of any other screw may short out the stator windings creating a risk of electrical shock WARNING To avoid...

Page 3: ...valve on hot water line For ease of installation leave the existing compression ring and nut from the angle stops on the hot and cold water lines 4 Remove the compression ring and nut from the adapter tees provided and slide on to opposite straight copper end Attach the existing nut and ring to the threaded end of the tee and tighten firmly 5 Connect the shut off valves to the new compression ring...

Page 4: ... operating a green LED located on the pump motor housing will illuminate The Green LED will only be on when the pump is activated and circulating water 3 To test manual starter button wait for hot water temperature to cool below 100 F approximately 20 30 minutes Press starter button to operate the pump The On Command should run for a short time and shut off automatically as in step 2 above 4 Check...

Page 5: ...he cold water tap A The water temperature sensor is loose or dislodged B The temperature sensitivity set ting now in place is too low so the pump is not shutting down soon enough Check the connection of the water temperature sensor to make sure it is firmly attached to the plug and casing Call 1 401 942 8000 for reset information 4 Water is not hot enough when pump shuts down A The temperature sen...

Page 6: ...1 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part Taco reserves the right to make changes in details of design construc tion or arrangement of materials of its products without notification TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES ANY WARRANTY I...

Reviews: