This page intentionally left blank

Summary of Contents for LeakBreaker LBW Series

Page 1: ...rce try to take the actuator off of the valve body without using the release clip Both locking posts should be firmly attached to the actuator If the actuator slides up the stem repeat the assembly process Instruction Sheet LeakBreaker 102 506 SUPERSEDES July 27 2017 EFFECTIVE January 31 2018 Plant ID No 001 4237 Warning Never place any body parts or objects into the valve opening doing so may res...

Page 2: ...e back of the controller plug the actuator wiring into the control panel port marked valve Two 2 sets of dry contacts are provided Each set includes normally open and normally closed connections They can be used to send a signal to any device requiring an open or closed signal such as a security system If using batteries install them into the battery holder Be sure to insert each battery in the co...

Page 3: ...r device and connect to the eLink server through your wireless net work It will no longer be visible in your available Wi Fi networks 5 Setting Up eLink Notifications email text Registering your device will set up the email and or cell phone number that will be alerted when the LeakBreaker operates or for status updates a Using an internet connected device go to the following web page in your devi...

Page 4: ...e valve should close the LED should flash red and the audible alarm should sound Once the valve closes press the mute button to silence the alarm a To reset the LeakBreaker completely dry off the sensor and then press the open button 1 2 3 4 Press Close Congratulations on the successful installation of your LeakBreaker 4 Installing Additional Sensors Up to ten 10 sensors may be daisy chained to th...

Page 5: ...220 F 1 to 105 C Service Potable water Seat Leakage Drop Tight Close Off Electrical Input 120VAC 60 HZ Output 6VDC 600mA Power Supply or 4 AA Batteries Auxiliary Switch Rating Class 2 1Amp 24Volts MATERIALS OF CONSTRUCTION Control Panel Body High Performance Engineered Polymer Actuator Body High Performance Engineered Polymer Gears High Performance Internally Lubricated Engineered Polymer Valve Bo...

Page 6: ...re wiring connections are solid and tight and the quick connect is all the way in Chirp every 60 seconds Solid Red with 4 red blinks AC power error Wrong power supply Use power supply provided Chirp every 60 seconds Continuous Red blinks Continuous Red blinks LeakBreaker has Triggered Sensor has detected water Determine the water source and correct Dry the sensor and reset the LeakBreaker Press th...

Page 7: ...7 This page intentionally left blank ...

Page 8: ...designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment...