FIG. 4

CAUTION:

Screw the device into the TEE fitting as shown.
Care must be taken to properly orient the device for
the direction of the flow. Do not tighten by grasping
the switch enclosure. Use the wrenching flats on the
bushing only. Turning radius required for mounting
the IFS is 3".

FIG. 5

Use the drawing at
right as a template
and trim at the dot-
ted arc when trim-
ming the appropri-
ate paddle for in-
termediate pipe
sizes.

CAUTION:

The paddle must
not touch the in-
side of the pipe or
bind in any way.

FIG. 3

Typical paddle arrangement
for 6" to 8" pipe, using smaller
flexible paddles for added
support and higher sensitiv-
ity.

NOTE:

When installing

rigid paddles

, do

not stack paddles.
Only install 

ONE

paddle that best
fits the pipe.

Summary of Contents for IFS01BF-1

Page 1: ...VAC Ambient Temperature Range 32 F 176 F 0 C 80 C Media Temperature Range 32 F 250 F 0 C 121 C Pipe Connections 1 NPT Brass on models IFSxxB 1 NPT 316 Stainless Steel on models IFSxxS Conduit Entrance Two openings for 1 2 conduit Usage For pipe sizes 1 8 Caution This device is not intended for applica tions in explosive environments Note IFSW Series available with NEMA 4 enclo sure for outdoor use...

Page 2: ...te paddle using the paddle template in Fig 5 The paddle must not touch the inside of the pipe or bind in any way Paddles smaller than the actual pipe size should be used for added support and higher sensitivity see Fig 3 The paddles must be prop erly attached and the screw that holds the paddle must be securely tightened For a 1 pipe application mount in a standard 1 x 1 x 1 tee Use a reducing tee...

Page 3: ...mounting the IFS is 3 FIG 5 Usethedrawingat right as a template and trim at the dot ted arc when trim ming the appropri ate paddle for in termediate pipe sizes CAUTION The paddle must not touch the in side of the pipe or bind in any way FIG 3 Typical paddle arrangement for 6 to 8 pipe using smaller flexible paddles for added support and higher sensitiv ity NOTE When installing rigid paddles do not...

Page 4: ... rates for 2 to 8 pipe sizes are averages which may vary 10 with the use of a 1 weldolet Flow rates for these sizes are calculated IFS01 IFS02 SWITCH INFORMATION IFSH1 IFSH2 SWITCH INFORMATION FIG 6B S N O I T A C I F I C E P S h c t i w S e t a u t c A o t d e r i u q e R M P G s e t a R w o l F l a c i p y T s n o i t a l l a t s n i e p i p l a c i t r e v r o F s e h c n i e z i S e p i P 1 4 ...

Reviews: