APPLICATION:

The Taco Wood Boiler Series Hi-Capacity circulators are
designed specifically for use on unpressurized outdoor
wood boiler applications. Features include a quiet running,
close-coupled, thermally protected motor assembly with
permanent split-capacitor and permanently lubricated
bearings. A stainless steel shaft, silicon-carbide mechanical
seal and non-ferrous impeller make the Wood Boiler Series
Circulator an ideal choice for years of maintenance-free
operation.

Note: Use Stainless Steel body circulators on open
systems for the best corrosion protection.

OPERATING SPECIFICATIONS:

Maximum Working Pressure:

150 psi (1034 kPa)

Maximum Operating Temperature:

225ºF (107ºC)

Electrical Rating:

115V/60Hz/1Ph

REMOVAL OF EXISTING PUMP FROM SYSTEM PIPING:

1. Disconnect and lock-out electrical supply to pump.

2. Close isolation valves on suction and discharge sides

of pump. If valves are not installed, the system may
need to be drained.

3. Remove capacitor box cover and disconnect electrical

supply lines to pump.

4. Loosen flange bolts and shift pump body slightly to

relieve any remaining system pressure. 

5. Remove flange nuts/bolts and pump from system. 

INSTALLATION OF WOOD BOILER SERIES
CIRCULATOR:

A. Location:

• Install pump with sufficient room for future inspection,

maintenance and service.

• It is recommended that isolation valves be installed on

the pump suction and discharge to simplify future ser-
vice or replacement without draining the system.

• Install pump at location with highest net positive suc-

tion head available (NPSHA), usually at the boiler supply
outlet.

Instruction Sheet

Outdoor Wood Boiler Series Hi-Capacity Circulator

102-349

SUPERSEDES: November 10, 2009 

EFFECTIVE: May 1, 2010

Plant ID# 001-3914

INSTALLER: Please leave these instructions for 

owner’s use.

CAUTION: Taco Wood Boiler circulators are
designed for indoor use only. Be sure boiler
enclosure is weather tight if installed on the
boiler.

CAUTION: This pump has a mechanical seal
which may require service. Allow access for
periodic inspection and leak detection.
Provide adequate drainage to prevent prop-
erty damage.

CAUTION: To prevent injury, allow system
water to cool to 100ºF before removing old
pump or draining system. Leave drain valve
open until service/replacement is complete.

WARNING: Do not use in swimming pool or spa
areas; pump has not been investigated for this
application.

WARNING: To avoid electrical shock, disconnect the
power supply to the circulator and the main electri-
cal unit.

CAUTION: When installing electrical connections,
do not apply mechanical loads to the capacitor
box; otherwise, retaining screws may be pulled out
of the housing, making circulator unusable.

CAUTION:
1. The addition of petroleum based fluids or cer-
tain chemical additives to systems utilizing TACO
equipment voids the warranty.
2. Use supply wires suitable for 90°C – ATTEN-
TION: Employer des fils d´alimentation adequats
pour 90°C.

CAUTION: Installations at higher elevations over
5000 feet must have higher fill pressure of 20 psi
minimum to prevent pump cavitation and flashing.
Premature failure may result. Adjust expansion
tank pressure to equal fill pressure. A larger size
expansion tank may be required.

Summary of Contents for 001-3914

Page 1: ...ghest net positive suc tion head available NPSHA usually at the boiler supply outlet Instruction Sheet Outdoor Wood Boiler Series Hi Capacity Circulator 102 349 SUPERSEDES November 10 2009 EFFECTIVE May 1 2010 Plant ID 001 3914 INSTALLER Please leave these instructions for owner s use CAUTION Taco Wood Boiler circulators are designed for indoor use only Be sure boiler enclosure is weather tight if...

Page 2: ... wires must be suitable for at least 90ºC 194ºF Wood Boiler Series circulators are thermally protected and do not require external overload protection 1 Be sure all electrical power to pump is disconnected and locked out before proceeding with wiring 2 Loosen capacitor conduit box screw and remove cover 3 Attach appropriate size connector to one of the two knock out holes in the capacitor conduit ...

Page 3: ... with soapy water and install new parts in the face plate recess Replace the face plate to its original posi tion Carefully tap the face plate evenly into the recess in the motor housing 7 Clean the impeller shaft before installing the new seal 8 Lubricate the impeller shaft with soapy water Do not install new seal on a dry impeller shaft or damage to seal may result 9 Slide the new carbon seal an...

Page 4: ...01 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part Taco reserves the right to make changes in details of design construc tion or arrangement of materials of its products without notification TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES ANY WARRANTY ...