background image

-5-

NEUTRAL

LINE

WIRING DIAGRAM

Removable

Green

Terminal

Plug

Terminal

Screws

GROUND

G

N

L

WARNING: SERVICING OF DOUBLE-INSULATED APPLIANCES. A double-insulated appliance is marked with one or 

more of the following: The words “DOUBLE INSULATION” or “DOUBLE INSULATED” or the double insulation sym-

bol (square within a square). In a double-insulated appliance, two systems of insulation are provided instead of 

grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding 

be added. Servicing a double-insulated appliance requires extreme care and knowledge of the system, and should 

be done by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to 

the parts they replace.

AVERTISSEMENT : ENTRETIEN DES APPAREILS À DOUBLE ISOLATION. Un appareil à double isolation est marqué avec 

un ou plusieurs des éléments suivants : les mots « DOUBLE INSULATION » ou « DOUBLE INSULATED » ou le symbole de 

double isolation (carré dans un carré). Dans un appareil à double isolation, deux systèmes d’isolation sont fournis 

plutôt que la mise à la terre ; aucun moyen de mise à la terre n’est fourni ni ne doit être ajouté. L’entretien d’un 

appareil à double isolation exige de grandes précautions et une connaissance approfondie du système, et doit 

être effectué par un technicien qualifié. Les pièces de rechange pour un appareil à double isolation doivent être 

identiques aux pièces remplacées.

4.   Wiring the circulator:

 Disconnect AC power supply. Remove terminal box cover. Attach a wiring connector    

 

 

into knockout hole. Use flexible conduit only. The green terminal plug may be removed to simplify wiring, then  

 

 

snapped back in place. Connect Line/Hot power to the L terminal, Neutral to the N terminal and Ground to the  

 

 

G terminal. See wiring diagram above. The 0034e is a double insulated circulator; grounding wire is not necessary but    

 

recommended for safety. Replace terminal box cover. Insert rubber cap plug provided to cover unused knockout hole.

4a.   Wiring the circulator for 0-10V DC Operation:

 (See Page 9)

5.  Start the circulator:

 When purging the system, it is recommended to run the circulator at full speed long    

 

 

enough to remove all remaining air from the bearing chamber. This is especially important when installing    

 

 

the circulator in the off-season. Turn the dial to the HIGH setting for maximum fixed speed. A blue LED will    

 

 

illuminate when the 0034e is powered on.

CAUTION: Never run the circulator dry or permanent damage may result.

ATTENTION: Ne laissez jamais le circulateur tourner à sec, des dommages permanents peuvent en résulter.

Full Speed Operation:

To run the pump at full speed during the fast fill, start-up and purge process, rotate dial to HIGH setting. The LED will 

change to blue. To return to the normal operating mode, turn dial to desired activeADAPT, LOW, MEDIUM, HIGH or 

0-10V setting.

Wiring Diagram

Summary of Contents for 0034e

Page 1: ...re on flanges for easier fit up Dual electrical knockouts and removable quick connect terminal strip for easy wiring Double insulated Whisper quiet operation BIO Barrier protects the pump from system contaminants SureStart automatic unblocking and air purging mode Rotatable control cover to allow any pump body orientation INSTALLATION WARNING Do not use in swimming pool or spa areas Pump has not b...

Page 2: ...NE 3 ZONE 1 ZONE 2 ZONE 3 ZONE 1 ZONE 2 ZONE 3 FC FC FC FC FC FC FC FC FC ZONE 1 ZONE 2 ZONE 3 ZONE 1 ZONE 2 ZONE 3 FC FC Optional Location FC FC ZONE 1 ZONE 2 ZONE 3 FC FC Optional Location FC FC Figure 2 PREFERRED PIPING FOR CIRCULATORS ON BOILER SUPPLY PREFERRED PIPING FOR CIRCULATORS ON BOILER RETURN PREFERRED PRIMARY SECONDARY PIPING FOR CIRCULATORS ON BOILER SUPPLY ...

Page 3: ...RIMARY SECONDARY PIPING FOR ZONE VALVES ON BOILER SUPPLY ALTERNATE PIPING FOR ZONE VALVES ON BOILER RETURN igure 3 MOD CON BOILER ZONE 1 ZONE 2 ZONE 3 ZONE 1 ZONE 2 ZONE 3 ZONE 1 ZONE 2 ZONE 3 ZONE 1 ZONE 2 ZONE 3 Figure 3 PREFERRED PIPING FOR ZONE VALVES ON BOILER SUPPLY ALTERNATE PIPING FOR ZONE VALVES ON BOILER RETURN PREFERRED PRIMARY SECONDARY PIPING FOR ZONE VALVES ON BOILER SUPPLY ...

Page 4: ...he system will result in immediate lubrication of the bearings It is always good practice to flush a new system of foreign matter before starting the circulator WARNING Risk of electric shock To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Follow all local electrical and plumbing codes AVERTISSEMENT Risque de choc électriqu...

Page 5: ...ualifié Les pièces de rechange pour un appareil à double isolation doivent être identiques aux pièces remplacées 4 Wiringthecirculator Disconnect AC power supply Remove terminal box cover Attach a wiring connector into knockout hole Use flexible conduit only The green terminal plug may be removed to simplify wiring then snapped back in place Connect Line Hot power to the L terminal Neutral to the ...

Page 6: ... on back page The 0034e has 5 Operating Settings activeADAPT Automatic self adjusting proportional pressure variable speed Violet LED LOW 13 feet of head constant pressure variable speed Orange LED MEDIUM 26 feet of head constant pressure variable speed Orange LED HIGH 34 feet of head max full fixed speed Blue LED 0 10V DC Analog external input or PWM pulse width modulation input from building con...

Page 7: ...te Q GPM 0 5 10 15 20 25 30 35 Head ft 0034e High Efficiency Circulator activeADAPT Range Purple LED activeADAPT activeADAPT Mode activeADAPT is an operating mode designed for constant circulation systems On this setting the circulator will sense changes in system flow and head conditions and adjust the operating curve automatically See activeADAPT operating range in the chart to the right Constan...

Page 8: ...High Efficiency Circulator Maximum Curve Fixed Speed Blue LED HIGH 5 0 10 15 20 25 30 35 40 45 50 55 Flow Rate Q GPM 0 5 10 15 20 25 30 35 Head ft HIGH Head 34 ft 0034e High Efficiency Circulator Maximum Curve Fixed Speed Blue LED Fixed Speed Mode At High setting the circulator always operates at full speed ...

Page 9: ...plug Figure 8 Ref 4 from the electronic board Figure 8 Ref 5 4 Insert the cable Figure 8 Ref 6 in the cable strain relief gland M12x1 5 Figure 8 Ref 7 provided in carton and screw it to the cover 5 Strip Minimum 25 the ends of the wires insert them into the connector as shown Figure 8 Ref 4 and fix them with screws Figure 8 Ref 8 6 Re connect the terminal plug to the electronic board replace the c...

Page 10: ...s state hysteresis See diagram below IMPORTANT If the input remains disconnected the circulator goes into Standby Mode Head ft PWM Pulse Width Modulation 2 4 6 8 0 0 6 8 2 4 10 16 12 14 20 22 18 26 28 30 32 24 34 36 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 54 52 Flow Rate Q GPM 0034e High Efficiency Circulator 0 10V DC Performance Curves 100 75 50 25 0 0 10V 4V 2V 8V 6V 10V P...

Page 11: ...rculator still doesn t run it will need to be replaced FAULTS CONTROL PANEL CAUSE S E I D E M E R S The circulator is noisy LED on Suction pressure is insufficient cavitation Increase the system suction pressure within the permissible range LED on Presence of foreign bodies in the impeller Disassemble the motor and clean the impeller Loud noises of water circulation Flashing white LED Air in the s...

Page 12: ...14 PL 50 PL 45 PL 36 PL 30 E90 1AAB Series 60 601 Series HV Series PR Series HV Series 100 NRF 45 NRF 36 ECOCirc XL 36 45 E 11 E 10 E 8 E 7 S 25 H 63 H 52 H 51 Astro 290 Astro 280 Astro 210 1050 1B 1050 1 1 4B Compass ECM TP E 32 40 UP 50 75 UPS 43 100 UPS 50 44 UP 43 75 UP S 43 44 UP 26 116 UP S 26 99 UP 26 96 UP 26 64 UPS 32 40 UPS 32 80 Magna 32 100 Magna 32 60 Alpha2 26 99 Stratos 1 25 x 3 35 ...

Page 13: ...duct or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part Taco reserves the right to make changes in details of design construc tion or arrangement of materials ...

Reviews: