52
Specifications
■
Power Supply Specifications
30R/30
30R/30
(Boiler/ High-pressure type)
60R/60
100R/100
200
Rated voltage
AC100~240V(±10%)
No. of phases
1-phases
No. of frequency
50/60Hz
Maximum current
2.0A
2.5A
Max. power consumption
200VA
250VA
Ave. power consumption
15W
18W
• Use the maximum current in calculating the required power capacity.
•
Be absolutely sure to use a commercial power source (the power supplied by an electric power company) for supply-
ing the power.
■
Power sources that cannot be used
1. Power sources in which an AC power regulator is installed
2. Power sources on the output side of an inverter
■
I/O Signal Specifications
Item
PW
PWT
PWM
Signal
Analog input
-
One port: analog signal (DC
4 to 20 mA, input resistance:
approximately 110
Ω
)
Digital
Input
One port: pulse signal
(no-voltage contact or open collector, maximum no. of
pulses: 1200 pulses/minute, minimum pulse width: 25 ms
[ON period])
One port: pump operation/stop signal(switchable)
(no-voltage contact or open collector, maximum no. of
pulses: 1200 pulses/minute, minimum pulse width: 25 ms
[ON period])
One port: pump operation/stop
signal(switchable)(no-voltage
contact or open collector,
maximum no. of pulses: 1200
pulses/minute, minimum pulse
width: 25 ms [ON period])
Output
One port: solenoid sync pulse signal (DC 25 V, 10 mA or less)
One port: batch warning signal (DC 25 V, 10 mA or less)
■
Operation mode
Manual operation
PW, DCLPW, CLPW
2 patterns
Stroke speed (0 to 300 strokes/min. in 1-stroke/min. increments)
Discharge capacity (in 0.1-ml/min. increments)
PWM, DCLPWM,
CLPWM
PWT, DCLPWT,
CLPWT
1 pattern
Stroke speed (0 to 300 strokes/min. in 1-stroke/min. increments)
Automatic
operation
Analog pro-
portional
control
PWM, DCLPWM,
CLPWM
Proportional band (PB/variable range: ±1 to ±999%)
Set point (SP/variable range: 0 to 100%)
Pulse pro-
portional
control
PW, DCLPW, CLPW,
PWT, DCLPWT,
CLPWT
Frequency-division (1/1 to 1/999)
Magnification (1 to 999)
Timer
PWT, DCLPWT,
CLPWT
Interval mode
(ON period: 1 to 9999 minutes; OFF period: 1 to 9999 minutes)
DAY mode (9 patterns for 1 day)
WEEK mode (1 pattern for each day of the week)
DAY + interval mode
WEEK + interval mode
DAY + interval mode + pulse proportional control
WEEK + interval mode + pulse proportional control