background image

      

Warning

Before using this instrument, please fully read all safety information 

carefully and strictly observe the safety rules and the precautions & 

warnings listed.

Safety information

      

Warning

To avoid possible electric shock or personal injury, and to avoid possible 

damage to the Tester or to the equipment being tested, adhere to the 

following rules:


The Structure

OPERATING INSTRUCTIONS

Switching on/off

For switching on the voltage tester, the following instructions are given:

High/low sensitivity

When first turned on, the tester is in low sensitivity mode(48-1000V) by 

default. Press and hold the sensitivity/flashlight button until the LED light is 

turned on, and then press the same button once to make the "S" button light 

up, the high sensitivity mode was chosen, and then you can test the wider

power(12~1000V). 

Every time you turn it on, the mode of the tester is still low sensitivity, you 

need to change its sensitivity again according to the instructions above.

Notes

High sensitivity

12~1000V

Low sensitivity

 48~1000V

LED Flashlight

When the tester is running, press the sensitivity / flashlight button for more 

than 2 seconds to turn on its LED light. 

Live/Null wire 

Live Wire Test

When the sensor end of the measuring pen is close to the object to be 

measured, the fast-paced buzzer alarms with its red indicator flashing 

quickly, and the LCD shows red light, indicating that the tested line is a LIVE 

WIRE.

Null Wire Test

When the sensor end is close to the object to be measured, the slow-paced 

buzzer alarms with its red indicator flashing slowly, and the LCD shows 

green light, indicating that the tested line is a Null Wire.

AC voltage detection

This tester can only be used to test AC voltage. We also have TACKLIFE 

meters for testing DC voltage. Please choose the right products according 

to your needs.

First, place the probe of the voltage detector near the AC power supply. 

When it senses AC voltage, the red indicator flashes. The stronger the 

voltage it senses, the more bright bars appear on the LCD screen, and the 

more frequently the buzzer alarms.

Note 1: 

As for the different structures of various sockets, the live/null wire of 

some socket may not be distinguished by the color of LCD light. In testing a 

socket, if the red light flickers both when you test live wire and null wire. At 

this time, please distinguish the live/null wire according to the number of 

brightness bars on the screen. When approaching the live wire, all the 

brightness bars will shows. (Sometimes a similar situation occurs in testing 

the Null wire forming circuit.)

Note 2: 

When you want to distinguish the Null wire from the Live wire, if they 

are very close to each other, please separate the two wires as far as 

possible for detecting. If they are inseparable, you can distinguish by the 

strength of the detected signal. A strong signal indicates the Live wire, and 

a weak signal indicates a Null wire.

Automatic shutdown

When no button on the tester is pressed and no voltage is sensored for 

approx. 3 minutes, it automatically switches off to save the batteries. 

 

Low battery indicator

When the battery voltage drops to less than 2.5 volts, the LCD will display "   

          " symbol to tell you that you need to replace batteries, though at this 

time, you can still use it for several times. When the battery voltage drops to 

less than 2.3 volts, the voltage detector will automatically turn off. Replace 

the battery as soon as the battery indicator appears. With a low battery, the 

tester might produce false readings that can lead to electric shock and 

personal injury.

- 03 -

Press the same button for more than 2 seconds to turn the light off.

When no button on the tester is pressed and no voltage signal is felt for 

approx. 3 minutes, it automatically switches off to save the batteries. 

Technical specifications

Replace the battery

Rotate the battery cover as shown below, then remove the old batteries and 

replace them with two new batteries according to the positive and negative 

instructions.

      

Warning

In order to avoid electric shock, voltage test should not be used before 

locking the battery cover.

Maintenance 

Beyond replacing the batteries, do not attempt to repair or service your 

multimeter unless you are qualified to do so and have the necessary 

calibration, performance testing and service instruments.

To clean it:

Wipe off debris using a moist and soft cloth. Do not use any cleaning agents 

or solvents.

Notes

After cleaning, the voltage detector must be dried before it can be 

used.

24-Month Warranty

In order to ensure the perfect experience of customers, we promise 24 

months of after-sales service. Within 24 months, you can ask for a refund or 

a replacement for any problem about this tester. There is our official website 

link on the warranty card, you can also directly contact the seller through 

your buyer account to ask for service about any TACKLIFE products.

Summary of Contents for VT02

Page 1: ...Model VT02 ...

Page 2: ...electrostatic field of sufficient intensity the voltage detector indicates the effective voltage If the field strength is too weak this tester can not detect the existence of voltage The results of voltage test may be affected by several factors including but not limited to the shielded wires cables the thickness and type of insulation the distance from voltage sources the differences in complete ...

Page 3: ...the same button once to make the S button light Probe NCV sensor LED flashlight Signal indicator LCD screen Power button sensitivity Flashlight With sensitivity indicator Battery compartment 02 Press the power button for 2 seconds to switch on this voltage tester The buzzer alarms and the LCD screen lights up To switch off the tester press the power button once the screen lights off shock Comply w...

Page 4: ...he tested line is a LIVE WIRE Null Wire Test When the sensor end is close to the object to be measured the slow paced buzzer alarms with its red indicator flashing slowly and the LCD shows green light indicating that the tested line is a Null Wire AC voltage detection This tester can only be used to test AC voltage We also have TACKLIFE meters for testing DC voltage Please choose the right product...

Page 5: ... wires as far as possible for detecting If they are inseparable you can distinguish by the strength of the detected signal A strong signal indicates the Live wire and a weak signal indicates a Null wire Automatic shutdown When no button on the tester is pressed and no voltage is sensored for approx 3 minutes it automatically switches off to save the batteries Low battery indicator When the battery...

Page 6: ...e battery cover as shown below then remove the old batteries and replace them with two new batteries according to the positive and negative instructions Warning In order to avoid electric shock voltage test should not be used before locking the battery cover Maintenance Beyond replacing the batteries do not attempt to repair or service your multimeter unless you are qualified to do so and have the...

Page 7: ...d 24 Month Warranty In order to ensure the perfect experience of customers we promise 24 months of after sales service Within 24 months you can ask for a refund or a replacement for any problem about this tester There is our official website link on the warranty card you can also directly contact the seller through your buyer account to ask for service about any TACKLIFE products ...

Page 8: ... one If you register on our website you will receive extra 24 months warranty How to return your Tacklife Products Contact support tacklife net with your order number We will issue you RMA and return address for your return Please fill out RMA info tear off this page and leave it inside your package We will issue replace return after receiving your return Return product details To get your returns...

Page 9: ...Warranty Registration We are glad to invite to register the warranty information at www tacklifetools com After registration you may kindly enjoy the exclusive service ...

Page 10: ...Shenzhen Take Tools Co Ltd www tacklifetools com www facebook com Tacklife US support tacklife net No B714 Niulanqian Building Minzhi Road Longhua District Shenzhen Guangdong China 518000 ...

Reviews: