Operation Manual
TW-6s
After You finish taking the measurements please return to the main menu with pressing the
OK[MENU]
button.
Memory function -
Memory
This function allows You to recall the latest
measurement values. Please press the
FUNKTION
button to switch between the stored
results. The first displayed result is the oldest
one. After You get to the last result the device
returns automatically to the first one. To return
to the main menu please press the
OK [MENU]
button.
Off function -
Off
After You accept this function with the
OK[MENU]
button the device turns off.
Substance function -
Subst
The substance function allows You to choose the material which will be measured. You have the
following possible choices:
galvanized steel / aluminium (
•
Zn/Al
);
steel (
•
Fe
);
reference point (
•
Ref
)
You can switch between the sheet materials with the
FUNKTION
button, to accept the selection
press the
OK [MENU]
button.
Reference point function -
Ref
To take the measurement in reference to a sample You can
use the reference point function. You can easily compare the
further results with a sample one.
After choosing this function on the display will appear a
Set
Ref
caption in the first line and in the second
-------
. In that
moment please put the sensor against the sample sheet,
wait until the result stabilizes and press the red button to set
the reference point.
Then, to take the measurement according to the reference point, You have to choose the
„reference point” option in the substance function menu. During the measurement a
Ref
caption
*
--------
Set.Ref
Meas.1
140um