background image

Thoma •  T

el./Fax: +48 95 741 11 62 • info@t4w

.eu • www

.t4w

.eu

Coating Thickness Gauge TW-2B

Operation Manual

art. 

nr

. 59247 

Summary of Contents for TW-2B

Page 1: ...Thoma Tel Fax 48 95 741 11 62 info t4w eu www t4w eu Coating Thickness Gauge TW 2B Operation Manual art nr 5924 7 ...

Page 2: ...peration Manual TW 2B Table of contents 1 Technical specifications 3 2 Getting started 3 3 Gauge manual 4 Guarantee TW 2B 8 The price of this product includes the recycling fee of 0 10 PLN Before You start to use the device please read this operation manual ...

Page 3: ...age much easier Before You start to use the device please place a new alkaline battery or a fully charged accu in the back side of the device s housing In order to do it please take off the battery flap and place correctly the battery or accu by connecting it to the clips on the cable Before You start to take measurements please place a new alkaline battery or a fully charged accu in the back side...

Page 4: ...normal batteries provide unsufficient power 2 Instead of a alkaline battery You can use a compatible fully charged accu 3 If the device seems to work improperly it can be caused by an empty battery or accu To take a measurement please put the device s sensor against the examined surface The sensor should adhere as flat as possible The examined surface should be clean and smooth otherwise the measu...

Page 5: ... select a function please press the OK MENU button Measure function Measur After You select this function the display will show Measur in the first line and um in the second The gauge is ready to take measurement After You put the sensor against the body of the car the result of the measurement will be shown in the second line To store the result please press the OK MENU button when taking the mea...

Page 6: ...eel Fe You can switch between the sheet materials with the FUNKTION button to accept the selection press the OK MENU button Delete function Delete Choose this function to delete all measurement values stored in the device s EEPROM internal memory After deleting the stored results the device returns to the main menu automatically Zeroing function Zero Use this function before You start to take meas...

Page 7: ...pears in the second line of the display otherwise the gauge will decalibrate WARNING While zeroing the calibration sheet should be placed on a flat stable non metalic surface e g do not place the sheet on the bodywork Also please avoid holding the sheet in Your hands as this may affect the operation Please note that zeroing is worth to be made when the measurement conditions are changing e g the t...

Page 8: ... be shipped to the Producer it happens on the shipper s responsibility and cost 8 The device will be not accepted by the Service if pt 6 is not kept if the defect is of no workmanship or 9 material nature if the warranty card is not filled out or the device is delivered with broken seal This guarantee shall not apply to damage caused through fire accident misuse incorrect adjustment or 10 repair i...

Reviews: