only  be  necessary  when  the  platform  is  empty.  When  the  zero  point  is 

obtained the display will show the indicator for zero. 

The  scale  has  an  automatic  zero  tracking  function  to  account  for 

minor drifting or accumulation of material on the platform. However you 

may need to press the 

ZERO

 key to rezero the scale if small amounts of 

weight  are  shown  when  the  platform  is  empty.(when  weight  more  then 

10% capacity, zero function disable) 

 

4.2 Taring 

        Zero  the  scale  by  pressing  the 

ZERO

  key  if  necessary.  The  zero 

indicator will be on. 

Place a container on the platform, a value for its weight will be displayed. 

Press  the 

TARE/UNIT

  key  to  tare  the  scale.  The  weight  that  was 

displayed  is  stored  as  the  tare  value  and  that  value  is  subtracted  from 

the display, leaving zero on the display. The "NET" indicator will be on. 

As  product  is  added  only  the  weight  of  the  product  will  be  shown.  The 

scale could be tared a second time if another type of product was to be 

added to the first one. Again only the weight that is added after taring will 

be displayed. 

When  the  container  is  removed  a  negative  value  will  be  shown.  If 

the scale was tared just before removing the container this value is the 

gross  weight  of  the  container  plus  all  product  that  was  removed.  The 

zero indicator will also be on because the platform is back to the same 

condition it was when the 

ZERO

 key was last pressed. 

 

4.3 Change weighing unit 

Press the 

TARE/UNIT

 key three second, weighing unit will change 

between kg and U

2

 

 

 

 

-2- 

5. PARAMETERS & CALIBRATION                               

5.1 Enter setting mode 

The  scale  has  9  parameters  that  can  be  set  by  the  user  plus  a 

method of entering the calibration section.     

To  set  parameters  or  calibration,  first  turn  off  the  weighing  scales, 

then  hold 

TARE/UNIT

  key  and  press 

ON/OFF

  key  until  display  show 

F0 CAL

”. 

 

5.2 Calibrate 

After  enter  setting  mode,  the  display  will  show  "

F0 CAL

".  press 

TARE/UNIT

 

key,  display  shows  “

UNLOAD

”,  empty  the  platter,  after 

STABLE  indicator  on,  press 

TARE/UNIT

  key  again,  display  shows  the 

calibrate  weight,  you  can  press 

ZERO

  key  to  select  calibrate  weight, 

after  you  select,  press 

TARE/UNIT

 

key, display shows “

LOAD

”, put the 

calibrate weight on, after STABLE indicator on, press 

TARE/UNIT

 key to 

sure, display shows “

SUCC

”, after T28 selfchecking again, T28 is ready 

for you. 

 

5.3 Change resolution 

After enter setting mode, the display shows “

F0 CAL

”, press 

ZERO

   

key,  display  shows  “

F1 inc

”,  press 

TARE/UNIT

  key  to  enter,  press 

ZERO

  key  to  select  increment,  press 

TARE/UNIT

  key  to  sure,  press 

ZERO

 key and 

TARE/UNIT

 key at the same time to escape. 

 

5.4 Check internal counts 

A

fter enter setting mode, display shows “

F0 CAL

”, press 

ZERO

 key 

twice, display shows “

F2 INP

”, press 

TARE/UNIT

 key to enter, display 

shows internal counts, press 

TARE/UNIT

 key to return setting mode. 

 

5.5 Set backlight mode 