Press weight on platform, after stable, you will hear beep on twice, 

you can add or remote weight now, scale will beep on again after stable, 

at last, remove all weight on platform, the last weight value will store in 

memory 

 

6 Animal Scales 

ROW can set as an animal scale when external resolution less than 

1/3000, about how to set it, see the technical manual of ROW. 

Let the animal on the platform, after some second, if reading data 

change  not a lot, you can hear beep sound and reading data will be 

locked. 

In reading data lock mode, if you add/remove big weight, display will 

still update and lock new reading data. 

 

7. CALIBRATION 

In weighing mode, press 

UNIT

  key  and 

PRINT/M+

  key 

together,  ”

Fo h-l

”.  Press 

TARE

  continuous until display will be 

shown  ”

prog

”.  Press 

ZERO

, display will be shown  “

pin

”.  Enter the 

password. Press 

G/N

UNIT

 and 

ZERO

, Display will be shown “

P1 ref

”, 

Press 

TARE

, display will be shown  “

P2 mod

”.  Enter the function by 

pressing 

ZERO

, display will be shown ”

sig ra

”, Select option ”

sig ra

”   

or ”

dua ra

” or ”

dua in

”. Enter the function by pressing 

ZERO

, display 

will be shown  “

dec

”,  Press 

TARE

  continuous until display will be 

shown  ”

cal

”.  Enter the function by pressing 

ZERO

, display will be 

shown “

linear

”, Press 

TARE

 to select for normal calibration ”

Nonlin

”. 

 

Enter the function by pressing 

ZERO

, display will be shown 

unload

”, Make sure there are no loads on the platform and wait few 

seconds for stable indicator on. Enter the function by pressing 

ZERO

display will be shown”

05.000

”. Currently adjustment, If want to change   

 

 

 

-6- 

Press the 

TARE

  key to tare the scale. The weight that was 

displayed is stored as the tare value and that value is subtracted from 

the display, leaving zero on the display. The "NET" indicator will be on. 

As product is added only the weight of the product will be shown. The 

scale could be tared a second time if another type of product was to be 

added to the first one. Again only the weight that is added after taring will 

be displayed. 

When the container is removed a negative value will be shown. If 

the scale was tared just before removing the container this value is the 

gross weight of the container plus all product that was removed. The 

zero indicator will also be on because the platform is back to the same 

condition it was when the 

ZERO

 key was last pressed. 

 

3.3 Weighing a sample 

To determine the weight of a sample first tare the empty container 

then place the sample in the container.    the display will show the weight 

and the units of weight currently in use.         

 

4 Check-Weighing 

4.1 About check-weighing 

Check-weighing is a procedure to cause an alarm to sound when 

the weight on the scale meets or exceeds values stored in memory.  

The memory holds values for a high limit and a low limit.   

Check mode 2:   

When check range, the display will show OK and the beeper will 

sound when the weight is between the limits.     

Check mode 3: 

When check range, the display will show OK and the beeper will 

sound when the weight is out of the limits.     

 

 

 

 