ROW weighing scales operation manual
REV: C1, June 2015
ROW weighing scales operation manual
Press weight on platform, after stable, you will hear beep on twice,
you can add or remote weight now, scale will beep on again after stable,
at last, remove all weight on platform, the last weight value will store in
memory
6 Animal Scales
ROW can set as an animal scale when external resolution less than
1/3000, about how to set it, see the technical manual of ROW.
Let the animal on the platform, after some second, if reading data
change not a lot, you can hear beep sound and reading data will be
locked.
In reading data lock mode, if you add/remove big weight, display will
still update and lock new reading data.
7. CALIBRATION
In weighing mode, press
UNIT
key and
PRINT/M+
key
together, ”
Fo h-l
”. Press
TARE
continuous until display will be
shown ”
prog
”. Press
ZERO
, display will be shown “
pin
”. Enter the
password. Press
G/N
,
UNIT
and
ZERO
, Display will be shown “
P1 ref
”,
Press
TARE
, display will be shown “
P2 mod
”. Enter the function by
pressing
ZERO
, display will be shown ”
sig ra
”, Select option ”
sig ra
”
or ”
dua ra
” or ”
dua in
”. Enter the function by pressing
ZERO
, display
will be shown “
dec
”, Press
TARE
continuous until display will be
shown ”
cal
”. Enter the function by pressing
ZERO
, display will be
shown “
linear
”, Press
TARE
to select for normal calibration ”
Nonlin
”.
Enter the function by pressing
ZERO
, display will be shown
“
unload
”, Make sure there are no loads on the platform and wait few
seconds for stable indicator on. Enter the function by pressing
ZERO
,
display will be shown”
05.000
”. Currently adjustment, If want to change
-6-
Press the
TARE
key to tare the scale. The weight that was
displayed is stored as the tare value and that value is subtracted from
the display, leaving zero on the display. The "NET" indicator will be on.
As product is added only the weight of the product will be shown. The
scale could be tared a second time if another type of product was to be
added to the first one. Again only the weight that is added after taring will
be displayed.
When the container is removed a negative value will be shown. If
the scale was tared just before removing the container this value is the
gross weight of the container plus all product that was removed. The
zero indicator will also be on because the platform is back to the same
condition it was when the
ZERO
key was last pressed.
3.3 Weighing a sample
To determine the weight of a sample first tare the empty container
then place the sample in the container. the display will show the weight
and the units of weight currently in use.
4 Check-Weighing
4.1 About check-weighing
Check-weighing is a procedure to cause an alarm to sound when
the weight on the scale meets or exceeds values stored in memory.
The memory holds values for a high limit and a low limit.
Check mode 2:
When check range, the display will show OK and the beeper will
sound when the weight is between the limits.
Check mode 3:
When check range, the display will show OK and the beeper will
sound when the weight is out of the limits.
-3-
4.2 Set limits
Summary of Contents for ROW Series
Page 1: ...ROW Weighing Scales...