T Scale ATW series Operation Manual Download Page 4

ATW weighting scales operation manual                           

   

                       

   

               

REV: C1, June 2012     

         

     

                                                      ATW weighting scales operation manual 

3. OPERATION   

3.1 ZEROING THE DISPLAY 

You can press the 

ZERO

 key at any time to set the zero point from 

which all other weighing and counting is measured, within 4% of power 

up zero. This will usually only be necessary when the platform is empty. 

When  the  zero  point  is  obtained  the  display  will  show  the  indicator  for 

zero. 

The scale has an automatic rezeroing function to account for minor 

drifting  or  accumulation  of  material  on  the  platform.  However  you  may 

need  to  press  the 

ZERO 

key  to  rezero  the  scale  if  small  amounts  of 

weight are shown when the platform is empty. 

 

3.2 TARING 

Zero  the  scale  by  pressing  the 

ZERO 

key  if  necessary.  The  zero 

indicator will be on. 

Place  a  container  on  the  platform,  a  value  for  its  weight  will  be 

displayed. 

Press the

 TARE

 key to tare the scale. The weight that was displayed 

is stored as the tare value and that value is subtracted from the display, 

leaving zero on the display. The "NET" indicator will be on. As product is 

added only the weight of the product will be shown. The scale could be 

tared a second time if another type of product was to be added to the first 

one. Again only the weight that is added after taring will be displayed. 

When the container is removed a negative value will be shown. If the 

scale was tared just before removing the container this value is the gross 

weight  of  the  container  plus  all  product  that  was  removed.  The  zero 

indicator  will  also  be  on  because  the  platform  is  back  to  the  same 

condition it was when the 

ZERO 

key was last pressed. 

 

 

 

-2- 

3.3    CHECK-WEIGHING 

Check-weighing is a procedure to cause an alarm to sound when the 

weight  on  the  scale  meets  or  exceeds  values  stored  in  memory.  The 
memory holds values for a high limit and a low limit.    Either limit can be 
used or both can be used. 

Press the 

LIMIT

 key.    The display will show the current High Limit with 

the left most digit flashing and the HI symbol on to the left of the display. 
To change the value shown use the 

LIMIT

 to select the digit to change.   

Then  use  the 

TARE

  key  to  increment  the  flashing  digit.    When  the 

desired value is shown press the 

ZERO

 key to accept the value.   

After pressing the 

ZERO

 key the display will then show the Low Limit, 

the LO symbol will be on to the left side of the display Enter the low limit 
in the same way the high limit was entered. 

After  pressing  the 

ZERO

  key  the  scale  will  return  to  weighing  with 

the Check-weighing function enabled. 

When  a  weight  is  placed  on  the  scale  the  arrows  will  show  if  the 

weight  is  above  or  below  the  limits  and  the  beeper  will  sound  as 
described below. 
BOTH LIMITS SET 

The display will show OK and the beeper will sound when the weight 

is between the limits.         
LOW LIMIT SET,   HIGH LIMIT is set to zero 

The display will show OK and the beeper will sound when 
the  weight  is  less  than  the  Low  Limit.    Above  the  Low 
Limit  the  display  will  show  HIGH  and  the  beeper  will  be 
off. 

HIGH LIMIT SET, LOW LIMIT is set to zero 

The  display  will  show  LOW  and  the  beeper  will  be  off   
when the weight is less than the High Limit.    Above the 
High Limit the display will show OK and the beeper will be 
on. 

BOTH LIMITS SET.      LOW is set greater than HIGH 

The  beeper  will  never  sound  and  the  display  will  show 
LOW if the weight is less that the LOW limit, and HIGH if 
the weight is greater than the Low Limit. 

-3- 