T-Fal FV32xx series Instructions Manual Download Page 7

5

3-Way automatic shut-off 

(depending on model)

The iron is equipped with an electronic system that will automatically cut
the power source to your iron if it is left vertically on its heel for more than
8 minutes, on its soleplate for more than 30 seconds or on its side for more
than 30 seconds.
The auto-off warning light (

fig.10

) will flash when the iron is in the shut

off mode.
•   To restart the iron, gently shake the iron until the warning light stops

flashing.

Storing your iron

•   Set the steam control lever to 

and unplug the iron.

•   Let the soleplate cool completely and empty the water tank. A small

amount of water may remain in the water tank.

• Wrap the cord around the heel of the iron.
•   Store the iron on its heel (

fig.11

).

When the auto-off warning
light is on, it is normal for the
temperature light to remain off. 

•  Set the temperature control dial to 

MAX

(

fig.4

).

•  Repeatedly press the 

Burst of Steam

button (

fig.7

) and

continuously move the iron over the fabric (

fig.9

).

•   Hold the iron a few inches from the fabric to avoid burning delicate

fabrics.

The steam is very hot. 
When using the vertical steam
function, always iron with the
garment on a hanger, never
while wearing it.

Cleaning the anti-scale valve

Maintenance and cleaning

It is recommended that you clean the anti-scale valve once a month to
remove scale build up on the valve.
Clean the anti-scale valve as noted below:
•  Unplug your iron and empty the water tank.
• Press 

the 

Self-Clean

ejection button (

fig.12a

) and remove the anti-

scale valve (

fig.12b

)

• Soak the valve (the black section only) in white vinegar or plain lemon

juice for 4 hours.

•  Rinse the valve under running water and put the anti-scale valve back.

Unplug your iron and let it cool
completely before cleaning it.
The iron will not function with-
out the anti-scale valve. 
Never touch the end of the
valve !

ENG

Cleaning the iron

It is recommended that you clean the iron once a month to slow down
scale build up and prolong the life of the iron.
Clean your iron as noted below:
• Unplug the iron, set the steam control lever to 

and fill the water

tank to 

MAX

.

• Place the iron on its heel, set the temperature dial to 

MAX

, plug in the

iron and wait for the indicator light to go out.

• Unplug the iron and place it horizontally over a sink.
• Press the 

Self-Clean

ejection button (

fig.12a

) and remove the anti-

scale valve (

fig.12b

).

• Gently shake the iron over the sink until all of the water (along with

impurities) runs out through the soleplate.

• At the end of the operation, put the anti-scale valve back into the iron

and allow it to heat for 2 minutes on its heel to dry the soleplate.

NOT FV32XX FTC 036635  5/12/06  11:39  Page 5

Summary of Contents for FV32xx series

Page 1: ...ULTRAGLIDE DIFFUSION ESP ENG FR Mod FV32xx series NOT FV32XX FTC 036635 5 12 06 11 39 Page c1...

Page 2: ...1 2 3 5 6 7 8 9 10 11 12 13 14 4 NOT FV32XX FTC 036635 5 12 06 11 39 Page c2...

Page 3: ...b a fig 7 fig 2 fig 5 fig 8 fig 11 fig 3 fig 6 fig 9 fig 12 fig 1 fig 4 fig 10 NOT FV32XX FTC 036635 5 12 06 11 39 Page c3...

Page 4: ...liquids 13 1The iron should always be turned OFF before plugging or unplugging from outlet Never yank cord to disconnect from outlet instead grasp plug and pull to disconnect 14 1Do not allow cord to...

Page 5: ...ecially when you are ironing on a corner of your ironing board Never direct the steam towards people or animals Your iron should be used and placed on a stable surface When you put your iron onto its...

Page 6: ...indicator light to turn on and off during ironing In order to avoid water leaking from the soleplate onto your garment Set the steam lever to when ironing silk or synthetic fabrics and set it to for...

Page 7: ...and cleaning It is recommended that you clean the anti scale valve once a month to remove scale build up on the valve Clean the anti scale valve as noted below Unplug your iron and empty the water tan...

Page 8: ...e washing it Do not add any descaling agents into the water tank Perform a self cleaning operation and consult the chapter What type of water should be used Perform the self cleaning operation and cle...

Page 9: ...lectrique n immergez jamais le fer ou sa base dans l eau ou dans un autre liquide 13 1 Le fer doit toujours tre mis en position ARR T avant de brancher ou de d brancher l appareil Ne tirez jamais sur...

Page 10: ...tout si vous vous tenez sur un coin de votre planche repasser Ne dirigez jamais la vapeur sur quelqu un ou sur un animal Votre fer doit tre utilis et pos sur une surface stable Lorsque vous posez votr...

Page 11: ...viter que l eau ne coule par la semelle sur vos v tements r glez le levier de vapeur lorsque vous repassez de la soie ou des tissus synth tiques et r glez le pour les lainages si vous devez baisser la...

Page 12: ...ape antitartre Entretien et nettoyage Il est recommand de nettoyer la soupape antitartre une fois par mois pour en enlever les accumulations de tartre Pour ce faire proc dez comme suit d branchez votr...

Page 13: ...de le laver N ajoutez pas de produits de d tartrage dans le r servoir eau Effectuez un autonettoyage et lisez la section Quel type d eau faut il utiliser Effectuez un autonettoyage et essuyez la semel...

Page 14: ...le nunca del cable con un golpe seco para desconectarlo sino del enchufe 14 1 Evite que el cable en contacto con superficies calientes Deje enfriar su aparato completamente antes de guardarlo y enroll...

Page 15: ...he en un ngulo de la tabla de planchar No dirija nunca el vapor hacia personas o animales Debe utilizar y poner la plancha sobre una superficie estable Cuando ponga la plancha en su reposa plancha ase...

Page 16: ...o la temperatura programada fig 5 Ponga el mando vapor fig 6 en la posici n consultando la tabla que figura a continuaci n Ajuste la temperatura y el vapor Es normal que el indicador se encienda y se...

Page 17: ...Auto limpieza fig 12a y retire la varilla antical fig 12b Deje la varilla la parte negra nicamente en remojo durante 4 horas dentro de un vaso con zumo de lim n natural Enjuague la varilla con agua de...

Page 18: ...ra los residuos calc reos en el agua del dep sito Realice una auto limpieza y consulte el cap tulo Qu agua utilizar Realice una auto limpieza y limpie la suela con una esponja h meda Aspire de vez en...

Page 19: ...17 NOT FV32XX FTC 036635 5 12 06 11 39 Page 17...

Page 20: ...18 NOT FV32XX FTC 036635 5 12 06 11 39 Page 18...

Page 21: ...19 NOT FV32XX FTC 036635 5 12 06 11 39 Page 19...

Page 22: ...036635 49 06 NOT FV32XX FTC 036635 5 12 06 11 39 Page 20...

Reviews: