Adjustment sensitivity on the Phono module MC
Adjust the input
sensitivity
(Gain)
The rotary switches on the left hand side are used to set the desired input
sensitivity for the left and right channels as shown in Table 3. The input
sensitivity can be adjusted in 8 steps with and 8 steps without subsonic
filter. The information about the requirements of your cartridge will be
included in the manufacturer’s specification for the pick-up system you
intend to use. Select
the value which is closest to the manufacturer’s
stated figure.
If you do not have access to the manufacturer’s
specification, a good starting point for sensitivity is position 4 (330 -
460 mV). This is the factory default setting.
It is essential to set the same value for both channels.
The subsonic filter attenuated rumble and low frequency noise below the
hearing band. This helps to avoid excessive excursions of the woofers.
To switch on the subsonic filter, please select one of the input
sensitivities (1...8) in the region marked 'SUBS ON'.
Input sensitivity
Switch position
Sensitivity [µV]
Subsonic off
Subsonic on
0
8
1200
…
>
1
9
700
…
1200
2
A
460
…
700
3
B
330
…
460
4
C
220
…
330
5
D
200
…
220
6
E
170
…
200
7
F
100
…
170
Table 3