background image

4

©

 

Copyright 2008 TAC All Rights Reserved.

F-24576-4

Optional Mounting

Eliminate the pipehead fitting by using the 22-022 thermostat 
conversion kit and the included instructions, plus the following:

1/4" Plastic Air Lines: Install the 1/4" barbed couplings into 
the air lines. Connect the tube assembly to the 3/16" end of 
these couplings.

1/4" Copper Air Lines: Solder the barbed couplings into the 
copper lines. The tube assembly can then be connected to the 
3/16" end of the couplings.

Bracket  

20-693

6 in. Tube Assembly with Eyelets

(included with thermostat)

Wall Plate

Thermostat

Cover

(order separately)

Mounting Screws

(included with thermostat)

Polyethylene Tubing

Air Supply

Branch

Main

Figure-5 Thermostat Mounted with 22-022

Conversion Kit, Using Wall Plate Only, to

Replace Competitive Thermostats.

Wall Plate

Pre-plumbed
Electrical Box
(optional)

Air Supply Tubing

Branch

(2) Thermostat

Mounting Screws

(included with thermostat)

3/16 in. Tygothane

Tubing with Eyelets

(included with thermostat)

Thermostat

Cover

(order separately)

Insert

1 Provided in the 22-023 thermostat conversion kit.

2 Optionally, the thermostat may be mounted with the #6 x 1 in. 

self-tapping screws provided in the 22-023 kit.

3   Use the #8 x 1 in. mounting screws provided in the 22-023 kit 

when mounting the wall plate directly to the wall, without an 
electrical box.

2

1

1

Wall

3/16 in. x 1/4 in.

Barbed Couplings

(included with thermostat)

Main

(2) #6 x 1 in.

Mounting Screws

(for electrical box mounting)

1

3

Figure-6 Thermostat Mounted with 22-023 Thermostat 

Conversion Kit.

Block

Branch

Main

Polyethylene

Tubing

Air Supply

Remove Locator

and Adaptor

20-710

Mortar Joint Fitting

(order separately)

20-693

6 in. Tube Assembly with Eyelets

(included with thermostat)  

Thermostat

Cover

(order separately)  

Mounting Screws

(included with thermostat)  

20-714

Wall Plate 

(included with

thermostat)  

Figure-7 Thermostat Installation Using

Pipehead in Masonry Wall.

Branch

Main

Polyethylene

Tubing

Air Supply

Cutouts

(partially formed

on underside)

20-689

Mounting Fitting with

8 ft. Copper Lines
(order separately)

20-716

Insulating Back Plate

(order separately)

20-693

6 in. Tube Assembly

with Eyelets

(included with

thermostat)  

Cover

(order separately)  

20-642

Mounting Ring and

Flathead Screws

(order separately) 

Thermostat

Mounting Screws

(included with thermostat)  

Figure-8 Surface Mounting of Thermostat,

Pipehead Application.

Summary of Contents for 2212-318

Page 1: ...setpoints All calibration functions are accessible from the front of the thermostat The use of a blank cover 21 928 is recommended with this device Other cover options may be utilized if desired Feat...

Page 2: ...nal 22 1057 C11 48 Euro white Plastic 21 960 C14 42 Satin Chrome Metal Blank Concealed Yes Internal 22 1060 C14 48 Euro white Plastic Table 4 Accessories Wholesale Number Replaces Model Description 20...

Page 3: ...the applicable figure Figure 2 through Figure 8 See Figure 12 for mounting dimensions Branch Main Polyethylene Tubing Air Supply 20 714 Wall Plate included with thermostat 21 473 Drywall Mounting ord...

Page 4: ...it 2 Optionally the thermostat may be mounted with the 6 x 1 in self tapping screws provided in the 22 023 kit 3 Use the 8 x 1 in mounting screws provided in the 22 023 kit when mounting the wall plat...

Page 5: ...hole Figure 10 or Figure 11 2 Be sure ambient temperature is between 65 and 75 F Turn the heating dial to 57 F and the cooling dial to 83 F 3 Adjust the deadband pressure by turning calibrating screw...

Page 6: ...cting models refer to Figure 11 and proceed with calibration as outlined under the procedures for the direct acting models Note If for some reason a thermostat gets completely out of adjustment and do...

Page 7: ...ar maintenance of the total system is recommended to assure sustained optimum performance FIELD REPAIR None Replace an inoperative thermostat with a functional unit DIMENSIONAL DATA 1 1 4 3 18 1 3 8 3...

Page 8: ...marks and registered trademarks are the property of their respective owners Information contained within this document is subject to change without notice F 24576 4 TAC 1354 Clifford Avenue P O Box 29...