BM801A INSTRUCTION MANUAL 

1. Introduction 

The  digital clamp  meter is  completely  portable, 3 1/2  digits 
LCD  display  instrument  for  measuring  AC  current,  DC and 
AC  voltage,  resistance,  diode  and  for  testing  audible 
continuity.  It  is  kind  of  ideal  facility  for  measurement  and 
monitor  in  electrician  materials,  electrical  equipments  and 
household electric appliances etc. 
 

2. Safety Information 

This  clamp  meter  has  been  designed  according  to 
IEC61010-1   
Please read this manual carefully before using the meter. 
2.1 Explanation of Symbols 

 

  Warning!  Important  safety  information  is  found  in 

the manual. 

     

 

 

risk of high voltage and electric shock! 

     

 

 

Double insulated. 

2.2 Never exceed the protection limit values indicated in the 
specifications for each range of measurement. 
2.3 Check the rotary switch and make sure it is at the correct 
position before measuring. 
2.4  Before  rotating  the  range  selector  to  change  functions, 
disconnect test leads from the circuit under test. 
2.5  Never  perform  resistance  measurements  and  continuity 
test on live circuits. 
2.6  Exercise  extreme  caution  when  measuring  live  system 
with voltage above 60V dc or 30V ac rms. 
2.7 Keep fingers behind the barriers while measuring current.     
2.8  Never  touch  exposed  wiring,  connections  or  live  circuit 
when attempting to take measurements.   
2.9  Change  the  battery  when  the  “

”  symbol  appears  to 

avoid incorrect data.

 

3.Specification 
3.1 General Specification: 

3.1.1  Digital  display:  3  1/2  digits  LCD  display  with 
maximum reading 1999. 
3.1.2 Jaw opening capability: 52mm. 
3.1.3 Data hold function: When the HOLD button is pushed, 
the display will keep the last reading and “DH” symbol will 
appear on the LCD until pushing it again.       
3.1.4 Polarity: “-” displayed for negative polarity. 
3.1.5 Over-range indication: “1” figure only on the display.   
3.1.5  Low  battery  indication: When  the  battery  is  under  the 

proper operation range, “

” will appear on the display. 

3.1.6  Auto  power off:  If there is  not any  operation with the 
keys  or  dials  within  about15  minutes,  the  meter  will  power 
itself off to save battery consumption. Dial the rotary switch 
to turn on the meter again. 
3.1.7  Operating  temperature  and  humidity:  0

C~40

C

70%RH. 

3.1.8  Storage  temperature  and  humidity:  -20

C~60

C

80%RH. 

3.1.9  Power  supply:  9V  battery,  NEDA  1604,  6F22  or 
equivalent. 
3.1.10 Dimension: 248

L

88

W

45

H

mm. 

3.1.11 Weight: about 360g (include battery). 
3.1.12 Accessory: Test leads, Instruction Manual. 

 
 
 
 

 
 
 
3.2 Electrical Specification: 

The  accuracy  specification  is  defined  as 

…%reading 

…count. 

At 23

5

C

70%RH. 

Funcuion 

Range 

Resolution 

Accuracy   

2A 

0.001A 

20A 

0.01A 

200A 

0.1A 

 

ACA 

1000A 

1A 

 
 

2%

10 

ACV 

700V 

1V 

1.2%

DCV 

1000V 

1V 

0.8%

 

2k

 

1

 

1.0%

 

Forward  current:  1mA.    Reversed  voltage: 
2.8V. 

 

Buzzer sounds at less than50

. Open circuit 

voltage: 2.8V, Test current: 1mA. 

Voltage    input impeadance

10M

 

ACA/ACV frequence range: 50~60Hz 

Overload protection: effective value 250V 

 
4. Operating Instruction 
4.1 Front Panel Description 

(1)

 

Transformer  jaws:  Pick  up  the  AC  current  flowing 
through the conductor. 

(2)

 

Trigger:  Press  the  lever  to  open  the  transformer.  When 
the lever is released, the jaws will close again.   

(3)

 

Rotary  switch:  This  switch  is  used  to  selected  functions 
and desired ranges as well as to turn on/off the meter.   

(4)

 

Data-hold button: The user may hold the present reading 
and keep it on the display by pressing the “Hold” button. 
When the  data is no  longer needed,  one  may release the 
data-hold operation by press the “Hold” button again. 

(5)

 

LCD display   

(6)

 

“V/

”  jack:  This  is  positive  input  terminal  for  volt  and 

ohms.   

(7)

 

“COM” jack: This is negative (ground) input terminal for 
all measurement modes except current. 

(8)

 

Barrier 

 

4.2 AC Voltage Measurement 

 

  WARNING!

 Maximum  Input  Voltage is 700V  AC/DC. 

Do  not  attempt  to  take  any  voltage  measurement  that  may 
exceed  to  avoid  electrical  shock  hazard  or  damage  to  this 
meter.   
(1)

 

Set  the  rotary  switch  at  AC700V  position.  Connect  the 
red  test  lead  to  “V/

”  jack  and  the  black  test  to  the 

“COM” jack. 

(2)

 

Connect  test  leads  across  the  source  or  loading  being 
measured and read voltage value on the LCD display. 

 
 
 
 
 