background image

 

 

SyxthSense Ltd 

 

 
Online Store: 

www.syxthsense.com

 

Copyright 

©

 2005 SyxthSense Ltd – 09/2005 

Enquiries: T: 

0870 20 80 100

   F: 

0870 20 80 200

 PS 

SW4.10

– 5/6 

 

 

 

 

 

 

 

 
 
 
 

Mechanical Installation 

The mechanical installation is carried out by fixing the device on a wall with two screws, taking 
advantage of the two holes with 60 mm. of distance between them. When tools are used close to the 
screws holes, particular attention must be used in order not to damage the electronics around. 
Once the electrical installation has been completed apply again the front plastic cover to close the 
case. Place the plastic front cover on the plastic base paying attention in that the holes for the 
indicators located on the front cover will fit in the relevant LEDs on the board, then press slightly until 
the four plastic side teeth snap. 

Wiring Instructions 

For a correct electrical installation of this telephone interface, follow the wiring diagram sketched 
below. At terminals 1..6 the changeover (SPDT) contacts of the output relays are available. These 
contacts are voltage free and can be used to drive electrical appliances when wired as described in 
the diagram. Terminals 7, 8 e 9 are used by the interface as inputs to acquire a state of an external 
contact. Terminal 7 is the common and is internally wired to the power supply ground. At these 
terminals can be wired any electrical contact as shown in the diagram.  
 

Note:  

It is very important to stress that IN1 and IN2 contacts must be voltage free; in other words it 

must be only wired to the telephone interface and not to any other electrical

 appliance.  

 

The wiring to the telephone line is made with the cable supplied with the device. This cable is 
provided with standard telephone plugs at each end. One of the ends must be plugged in the female 
connector located on the board inside the interface, meanwhile the other must be plugged in the 
telephone socket located in the installation site. In case the available telephone socket in not 
compatible with the supplied cable a proper adaptor must be used: these adaptors are usually 
distributed in electrical shops. In case the telephone interface requires a different wiring to the 
telephone line, it is important to keep in mind that the device must be wired in parallel to the existing 
line, therefore in parallel with other phone line machines. It is not mandatory to respect the polarity of 
the wires to be connected to the telephone line. 
 
The device is powered with 12Vdc: this is made with the supplied external 230V~/12V power supply 
whose connector must be plugged in the connector located on the interface board as shown in the 
diagram.

 

 

 

-

 

+

 

230V~ / 

12V- 

100mA

 

EXTERNAL POWER
SUPPLY

FIXED LINE
TELEPHONE
PLUG

12VDC

TELEPHONE

LINE

POWER

 

Reviews: