background image

 
 

uLory User Guide 

 

 

 

 

 

   

 

 

 

3

This equipment has been tested and found to comply with the limits for a Class A digital 
device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable  protection  against  harmful  interference  when  the  equipment  is  operated  in  a 
commercial environment. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the user will be required to correct 
the interference at his own expense. 
 
Caution 
THE  GRANTEE  IS  NOT  RESPONSIBLE  FOR  ANY  CHANGES  OR  MODIFICATIONS  NOT 
EXPRESSLY  APPROVED  BY  THE  PARTY  RESPONSIBLE  FOR  COMPLIANCE.  SUCH 
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. 
 
IMPORTANT NOTE : FCC RF Radiation Exposure Statement 
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled 
environment. 
This  equipment  should  be  installed  and  operated  with  a  minimum  distance  of  20 
centimeters between the radiator and your body. This transmitter must not be co-located or 
operating in conjunction with any other antenna or transmitter. 
 
This  device  complies  with  part 15  of  the  FCC  Rules.  Operation  is  subject to  the following 
two conditions: 
(1) This device may not cause harmful interference, and   
(2) this device must accept any interference received, including interference that may cause 
undesired operation. 

Summary of Contents for uLory

Page 1: ...uLory User Guide Version 1 0 April 8th 2019...

Page 2: ...ils of Revision April 8th 2019 1 0 All New Copyright 2018 SystemBase Co Ltd All rights reserved Website http www sysbas com Tel 82 2 855 0501 Fax 82 2 855 0580 16F 1601 Daerung Post Tower 1 288 Digita...

Page 3: ...nse Caution THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE...

Page 4: ...ATURE 5 3 COMPONENTS 6 4 HARDWARE 7 4 1 Specification 7 4 2 LED 8 4 3 Drawing of Device 9 5 HOW TO CONNECT 9 5 1 Install USB Driver 9 5 2 Check USB Serial Port 10 6 HOW TO USE 10 6 1 Switch Setting Ta...

Page 5: ...of technology of Low Power Wide Area LPWA capable of transmitting small amounts of data over long ranges enables communications up to 20 km in open terrain 2 FEATURE Support low power and mid and lon...

Page 6: ...uLory User Guide 6 3 COMPONENTS COMPONENTS ORDER NUMBER uLory 1010UIL 2 625dBi Antenna Quick Manuals SystemBase Covenant uLory 1010UIL Package 2 625dBi Antenna Product Brochure SystemBase Covenant...

Page 7: ...CATION Wireless Interface Frequency Band 917 923MHz Modulation LoRa Antenna 2 625 dBi Gain Load Antenna Wired Interface Standard USB 2 0 A Type Signal USB DP DM Display LED TXD RXD RDY Operating Envir...

Page 8: ...ode Default Blink Interval of 0 1 sec Setup Mode RXD RED On Reception of Data from LoRa to USB Port Off TXD GREEN On Transmission of Data from USB Port to LoRa Off If the input voltage level is lower...

Page 9: ...RDY LED of the device will blink in the 0 1 second interval under the Setup Mode and in the 0 5 second interval under the Operation Mode See 4 2 in the Manuals for details of LED operation 5 1 Instal...

Page 10: ...ng a driver 6 How to Use Users should adjust setting of Serial interface communication speed parity bits and flow control and LoRa channel Spreading Factor for the communication between uLorys or with...

Page 11: ...mmunication between PC and a device via uLory while LoryNet Mode is used for the communication in a structure of LoryNet Packet General Communication Mode Setup via command Set and open USB Serial Por...

Page 12: ...uLory User Guide 12 switching Mode Switch off Switch 1 to change it back to the Operation Mode after the completion of setup...

Page 13: ...es are not shown Only the changed AES KEY and AES IV values are shown AT PTYPE Mode 1 0 1 0 LoryNet Mode 1 General Communication Mode 0 Setting for connection and communication with LoryNet platform 1...

Page 14: ...z 11 921 5MHz 12 921 7MHz 13 921 9MHz 14 922 1MHz 15 922 3MHz 16 922 5MHz 17 922 7MHz 18 922 9MHz 19 923 1MHz 20 923 3MHz Change channels of LoRa AT SFT Spreading Factor 9 7 12 Change Spreading Factor...

Page 15: ...AT HF Hardware Flow Control 0 OFF 1 RTS CTS Set flow control AT DMT Time 5 1 255 Unit 10ms Example 5 50ms Used to collect serial data and transmit it to LoRa Wait for the next data after the last dat...

Page 16: ...Hex except 0x for ETX Set the length in AT ETXL Length before entering the desired length For example in order to register number 1 2 and 3 users firstly input AT ETXL 3 and then AT ETXL 31 32 33 AT D...

Page 17: ...nd firmware update and find the detailed instructions on the use in the LoryView manual LoryNet Mode LoryNet is an IoT platform with virtual cable that enables smooth communication as if it were readi...

Page 18: ...remote monitoring and control such as smart street lighting smart metering smart farm smart farming and smart factories As it boasts a communication range of the maximum of 20km in open terrain it can...

Reviews: